Section 7: Specifications and Parts List
Aspire S Hardware Manual
Section 7: Speci
fi
cations and Parts List
◆
7-13
7
Cabling Requirements
1. Do not run station cable in parallel with the AC source, telex or computer, etc. If the cables are
near cable runs to those devices, use shielded cable with grounded shields or install the cable in
conduit.
2. When cables must be run on the
fl
oor, use cable protectors.
3. Cable runs for key telephones, single line telephones, Door Boxes, CTA or CTU adapters, and
2PGDAD Modules must be a dedicated, isolated cable pair.
4. The Telco RJ21X and cross-connect blocks should install to the right of the cabinet.
Extension blocks and cross-connect blocks should be installed to the left of the cabinet.
Cable Requirements
Device
Cable Type
Cable Run Length (ft)
Notes
Key Telephone, DSS
Console:
ICT 2-wire 26 AWG
ICT 2-wire 24 AWG
ICT 2-wire 22 AWG
656 (200 meters)
984 (300 meters)
1640 (500 meters)
Single Line Telephone,
Analog Terminals:
20mA Setting:
35mA Setting:
ICT 2-wire 26 AWG
ICT 2-wire 24 AWG
ICT 2-wire 22 AWG
1,500 ohm loop resistance
900 ohm loop resistance
6,561 (2000 meters)
10,498 (3200 meters)
17,388 (5300 meters)
Includes resistance
of telephone
SLT Adapter:
SLTAD to SLT:
ICT 2-wire 26 AWG
ICT 2-wire 24 AWG
ICT 2-wire 22 AWG
500 ohm loop resistance
(including phone’s DC
termination)
656 (200 meters)
984 (300 meters)
1640 (500 meters)
2PGDAD Adapter:
ICT 2-wire 26 AWG
ICT 2-wire 24 AWG
ICT 2-wire 22 AWG
656 (200 meters)
984 (300 meters)
1640 (500 meters)
Door Box to 2PGDAD:
ICT 2-wire 26 AWG
ICT 2-wire 24 AWG
ICT 2-wire 22 AWG
200 ohm loop resistance
(excluding internal resis-
tance of Door Box)
656 (200 meters)
984 (300 meters)
1640 (500 meters)
Using Under Carpet Cable:
The cable is not twisted, but
fl
at parallel wire. Good impedance balance cannot be expected and reduces
the cable length to no more than 300m when using the
fl
at cable.
PC to CTA
Serial Straight Thru
Cable
49.21 (15 meters
D-Sub 9-Pin Female
(PC) to D-Sub 9-Pin
Male (CTA)
CTA to Printer
Serial straight cable
49.21 (15 meters)
D-Sub 9-Pin Female
(Printer) to D-Sub
9-Pin Male (CTA)