12
Debugging Part Program
100
The different function and axis locking possibilities can be combined optionally. An axis, e.g. Z
axis and the functions can be locked simultaneously.
L
Note:
About the different locking possibilities turn to the machine tool builder for an information
material.
12.5 Test Run
Softkey TEST can be reached on OPERATOR’S PANEL or POSITION screens. After
pressing the
action menu
key
F5
CONDITIONS action menu must be selected, than
softkey TEST needs to be pressed.
If NCT machine control board is used select the
button.
The TEST state is indicated by caption TEST in the 8
th
field of the status bar.
When the key is activated:
– the interpolator does not command any movement on any axis towards the position control
loop, and
– no function is executed by the PLC.
The TEST state can be applied for
the syntactic and graphic test of
programs. The program execution
(the interpolation) is much faster
than it is in case of the simul-
taneous switched on state of
MACH LOCK and DRY RUN.
The position display and the
graphic position display show the
path done.
If
button TEST is
inactivated, than the current axis positions can be seen again in the position display of control.
L
Note:
Generally the TEST
button can be switched in one of the manual modes in case the
axes are in stopped state. For more turn to the machine tool builder for an information
material.
Содержание 100T
Страница 1: ...NCT 100T NCT 990T NCT 2000T Controls for Lathes Operator s Manual Valid from software version x 057 ...
Страница 9: ...1 Operator s Panel 9 Operator s panel with 15 color monitor and with optional Machine control board ...
Страница 37: ...3 4 OFFSETS Screens 37 On the figures below the interpretation of the imaginary tool nose number Q can be seen ...
Страница 143: ...Notes 143 Notes ...