14.3
Listing of Global Messages
Error
Code
Message
Description
Canceling and Re-
pairing Method
125
999
SHORT MON
This message is displayed, if MON (Ma-
chine ON) output of control is short-cir-
cuited or overloaded.
This message is generated in EMG state.
This message causes
EMG state and loss
of reference point. It
can be canceled by
RESET.
1020
POSITION ERROR
This message is displayed, if the position
lag does not reach the value specified at
parameter within 5 seconds after the
interpolator has stopped. The above detec-
tion is executed in case of command G00
if parameter 1241 POSCHECK is 1, or in
case of feed movement in states G9 and
G61.
The message is can-
celed by RESET
key. In order to
repair the cause of
error, the input
offsets of the drives
must be zeroed.
1100
REFERENCE POINT t1
This message is displayed, if the reference
point switch has not been found within the
distance specified at parameter
REFDIS
(or if it cannot stop within that distance).
Value of t is the name of the axis: X, Y,
Z, U, V, W, A, B, C.
In the error code (1100, 1110, 1120, ...)
the digit on local value 10 (0, 1, 2, ...) +1
is the physical axis number.
The message is can-
celed by RESET
key.
1110
1120
1130
1140
1150
1160
1170
1101
REFERENCE POINT t2
This message is displayed if it cannot run
off the switch within the distance
specified at parameter
SWLENGTH
.
Value of t is the name of the axis: X, Y,
Z, U, V, W, A, B, C.
In the error code (1101, 1111, 1121, ...)
the digit on local value 10 (0, 1, 2, ...) +1
is the physical axis number.
The message is can-
celed by RESET
key.
1111
1121
1131
1141
1151
1171
Содержание 100T
Страница 1: ...NCT 100T NCT 990T NCT 2000T Controls for Lathes Operator s Manual Valid from software version x 057 ...
Страница 9: ...1 Operator s Panel 9 Operator s panel with 15 color monitor and with optional Machine control board ...
Страница 37: ...3 4 OFFSETS Screens 37 On the figures below the interpretation of the imaginary tool nose number Q can be seen ...