background image

 

NCR

 

SelfServ™

 

84

 

Walk

Up

 

ATM

 

Site

 

Preparation

i

NCR

 

Proprietary

 

Information

 ‐ 

not

 

to

 

be

 

disclosed

 

or

 

reproduced

 

without

 

written

 

consent.

 

©

 

2017,

 

2018

 

by

 

NCR

 

Corporation,

 

Atlanta,

 

Georgia,

 

U.S.A.

 

http://www.ncr.com.All

 

Rights

 

Reserved

B006

7519

G000

Contents

Introduction

Audience ...............................................................................................1

 ‐ 

1

About

 

This

 

Document ...........................................................................1

 ‐ 

1

Revision

 

Record ....................................................................................1

 ‐ 

1

Customer

 

Responsibilities

Notice ...................................................................................................2

 ‐ 

1

Site

 

Compliance ....................................................................................2

 ‐ 

1

Customer

 

Actions .................................................................................2

 ‐ 

1

Standards

 

Compliance

Radio

 

Frequency

 

Interference ..............................................................3

 ‐ 

1

FCC

 

Radio

 

Frequency

 

Interference

 

Statement ................................3

 ‐ 

1

Canadian

 

Class

 

A

 

Device

 

Declaration...............................................3

 ‐ 

1

Safety ....................................................................................................3

 ‐ 

1

Safety

 

Directive................................................................................3

 ‐ 

1

Harmonised

 

Safety

 

Standard...........................................................3

 ‐ 

1

Electromagnetic

 

Compatibility

 

(EMC)...................................................3

 ‐ 

1

Immunity

 

Standards ........................................................................3

 ‐ 

1

EMC

 

Directives.................................................................................3

 ‐ 

1

Emission

 

Standards..........................................................................3

 ‐ 

1

Additional

 

Requirements

 

for

 

220V

 ‐ 

240V

 

Units .............................3

 ‐ 

1

Accessibility ..........................................................................................3

 ‐ 

1

Product

 

Overview

General

 

Description ..............................................................................4

 ‐ 

1

Options ............................................................................................4

 ‐ 

1

Acoustics...............................................................................................4

 ‐ 

1

Heat

 

Dissipation....................................................................................4

 ‐ 

1

Product

 

Identification...........................................................................4

 ‐ 

1

Site

 

Requirements

Positioning

 

the

 

ATM .............................................................................5

 ‐ 

1

Floor......................................................................................................5

 ‐ 

1

Doorways

 

and

 

Corridors .......................................................................5

 ‐ 

1

Wall.......................................................................................................5

 ‐ 

1

Wall

 

Cavity.......................................................................................5

 ‐ 

1

Installing

 

Through

 

a

 

Glass

 

Wall........................................................5

 ‐ 

1

Collar

 

Tolerance...............................................................................5

 ‐ 

1

Ambient

 

Lighting...................................................................................5

 ‐ 

1

Task

 

Lighting .........................................................................................5

 ‐ 

1

Temperature

 

and

 

Humidity ..................................................................5

 ‐ 

2

Normal

 

Operating

 

Range

 

(Interior

 

Environment)............................5

 ‐ 

2

Normal

 

Operating

 

Range

 

(Exterior

 

Environment) ...........................5

 ‐ 

2

Storage

 

Range

 

(Up

 

To

 

Three

 

Months) .............................................5

 ‐ 

2

Transit

 

Range

 

(Up

 

To

 

One

 

Week) ....................................................5

 ‐ 

2

Extreme

 

Power

 

On

 

Range

 

(Up

 

To

 

One

 

Hour) ..................................5

 ‐ 

2

Barometric

 

Pressure ............................................................................. 5

 ‐ 

2

Power

 

Requirements

AC

 

Power

 

Requirements....................................................................... 6

 ‐ 

1

Input

 

Voltage

 

Setting............................................................................ 6

 ‐ 

1

Grounding............................................................................................. 6

 ‐ 

1

Transient

 

Protection............................................................................. 6

 ‐ 

1

Cable

 

Requirements

Cable

 

Preparation................................................................................. 7

 ‐ 

1

Data

 

Line

 

Transient

 

Protection............................................................. 7

 ‐ 

1

Alarm

 

Interface

 

Cables ......................................................................... 7

 ‐ 

1

Basic

 

Alarm

 

Cable ............................................................................ 7

 ‐ 

1

Enhanced

 

Alarm

 

Cable .................................................................... 7

 ‐ 

1

Remote

 

Status

 

Monitor ........................................................................ 7

 ‐ 

2

Shortening

 

the

 

Cable....................................................................... 7

 ‐ 

2

Remote

 

Relay

 

Cable.............................................................................. 7

 ‐ 

2

Ethernet

 

Standard

 

Cable ...................................................................... 7

 ‐ 

2

Power

 

Cable.......................................................................................... 7

 ‐ 

2

Decals

Advert

 

Window .................................................................................... 8

 ‐ 

1

Advert

 

Collar

 

or

 

Open

 

Advert

 

Collar................................................ 8

 ‐ 

1

Entry/Exit

 

Decals .................................................................................. 8

 ‐ 

1

Variant

 

Details

 ‐ 

CEN

 

I,

 

Standard

 

Collar

 

ATM

Package

 

Dimensions ............................................................................. 9

 ‐ 

1

ATM

 

Dimensions................................................................................... 9

 ‐ 

1

Weight

 

and

 

Floor

 

Loading .................................................................... 9

 ‐ 

1

Standard

 

Security

 

Enclosures .......................................................... 9

 ‐ 

1

Cable

 

Entry ........................................................................................... 9

 ‐ 

1

Facia

 

Items............................................................................................ 9

 ‐ 

2

15”

 

Touchscreen.............................................................................. 9

 ‐ 

2

19”

 

Touchscreen.............................................................................. 9

 ‐ 

2

Touchscreen

 

Dimensions ................................................................ 9

 ‐ 

2

Heights

 

and

 

Depths ......................................................................... 9

 ‐ 

2

Distance

 

for

 

Voice

 

Guidance ........................................................... 9

 ‐ 

2

Security

 

Bolts........................................................................................ 9

 ‐ 

3

Bolt

 

Holes ............................................................................................. 9

 ‐ 

3

Short

 

Sleeve..................................................................................... 9

 ‐ 

3

Long

 

Sleeve...................................................................................... 9

 ‐ 

3

Hole

 

in

 

the

 

Wall .................................................................................... 9

 ‐ 

4

Hole

 

at

 

Optimum

 

Height ................................................................. 9

 ‐ 

4

Hole

 

at

 

Lowered

 

Height................................................................... 9

 ‐ 

4

Hole

 

in

 

the

 

Wall

 

Overlap

 ‐ 

Standard

 

Collar

 ‐ 

ATM........................... 9

 ‐ 

5

Vents

 

Location

 ‐ 

Air

 

Flow...................................................................... 9

 ‐ 

5

Clearances

 ‐ 

Topbox

 

Door .................................................................... 9

 ‐ 

5

Clearances

 ‐ 

Corridor............................................................................ 9

 ‐ 

5

Servicing

 

Areas

 ‐ 

Optimum

 ‐ 

Single

 

ATM.............................................. 9

 ‐ 

6

Short

 

Sleeve .................................................................................... 9

 ‐ 

6

Long

 

Sleeve ..................................................................................... 9

 ‐ 

6

Servicing

 

Areas

 ‐ 

Optimum

 ‐ 

Side

 

By

 

Side ............................................ 9

 ‐ 

7

Short

 

Sleeve .................................................................................... 9

 ‐ 

7

Long

 

Sleeve ..................................................................................... 9

 ‐ 

7

Servicing

 

Areas

 ‐ 

Minimum

 ‐ 

Single

 

ATM ............................................. 9

 ‐ 

8

Short

 

Sleeve .................................................................................... 9

 ‐ 

8

Long

 

Sleeve ..................................................................................... 9

 ‐ 

8

Servicing

 

Areas

 ‐ 

Minimum

 ‐ 

Side

 

By

 

Side ............................................ 9

 ‐ 

9

Short

 

Sleeve .................................................................................... 9

 ‐ 

9

Long

 

Sleeve ..................................................................................... 9

 ‐ 

9

Содержание SelfServ 84 Walk-Up

Страница 1: ...NCR SelfServ 84 Walk Up Standard Collar ATM Site Preparation B006 7519 G000...

Страница 2: ...NCR s copyright notice must be included It is the policy of NCR Corporation NCR to improve products as new technology components software and firmware become available NCR therefore reserves the right...

Страница 3: ...onths 5 2 Transit Range Up To One Week 5 2 Extreme Power On Range Up To One Hour 5 2 Barometric Pressure 5 2 Power Requirements AC Power Requirements 6 1 Input Voltage Setting 6 1 Grounding 6 1 Transi...

Страница 4: ...h page has two or three columns laid out as follows Where left and right side are stated the ATM is viewed from the front facia side of the ATM All plan views are from the top unless otherwise stated...

Страница 5: ...The responsibility for ensuring that the site is prepared in compliance with this document remains with the customer For information and guidance purposes only a list is provided in general terms of...

Страница 6: ...ds The ATM complies with the following requirements for radiated and conducted immunity EN 55024 1998 A1 2001 A2 2003 As per the requirements of EN55024 the ATM complies with the requirements of the f...

Страница 7: ...e with a medium to high feature functionality configuration Heat dissipation figures are largely unaffected by transactional rates PRODUCT IDENTIFICATION The illustration below is typical of the layou...

Страница 8: ...M can be found in the Variant Details sections DOORWAYS AND CORRIDORS Make sure that doorways and corridors leading to your point of installation are wide enough to allow the package to pass through o...

Страница 9: ...d humidity to a maximum humidity at 0 C 32 F Normal Operating Range Interior Environment Temperature 0 C to 40 C 32 F to 104 F Relative Humidity 20 to 80 Dew Point Temperature Restriction 26 C 79 F ma...

Страница 10: ...termittent short circuits and switching transients can be introduced on to power lines Such transient energy can be very damaging to electronic hardware and can also cause data corruption Under these...

Страница 11: ...ne of two options a basic alarm system or an enhanced alarm system A stabilised non interruptible power supply must be provided through the external alarm system The alarm interface cable wiring must...

Страница 12: ...rm to the following specification and wiring Remove a 20 mm 0 79 in section of the outer sleeve 100 mm 3 94 in from the ATM end of the cable Take care not to cut through the cable shielding ETHERNET S...

Страница 13: ...rif typeface should be used Tiresias is recommended The text size should be at least 14 point and larger where possible Where tactile decals are required they should be designed in line with specific...

Страница 14: ...7 in 770 mm 30 31 in 832 mm 32 76 in 664 mm 26 14 in 800 mm 31 50 in 801 mm 31 54 in 259 mm 10 20 in 226 mm 8 90 in 66 mm 2 60 in Note 1 60 mm 2 36 in 681 mm 26 81 in 502 mm 19 76 in 62 mm 2 44 in Not...

Страница 15: ...7 in 165 mm 6 50 in Contactless Card Reader behind Facia 915 mm 36 02 in 1033 mm 40 67 in 165 mm 6 50 in PIN Pad Number 5 Key 849 mm 33 43 in 967 mm 38 07 in 136 5 mm 5 37 in Private Audio 780 mm 30 7...

Страница 16: ...high tensile minimum ISO property class 8 8 Washers Type flat steel as per DIN7349 or equivalent Size M16 5 8 in Outer diameter no greater than 40 mm 1 58 in Minimum thickness 6 mm 0 2 in BOLT HOLES T...

Страница 17: ...mum 12 99 in 203 mm 330 mm 534 mm 21 02 in B 18 mm 0 71 in 625 mm 24 61 in A Hole in Wall ATM Base View from Inside Building Plinth Sidewalk increase to 635 mm 25 00 in if ATM installed with cash came...

Страница 18: ...hown assume the ATM is being moved using equipment that does not extend beyond the ATM or packaging A surrounding clearance of 6 mm 0 24 in has been allowed in the dimensions 47 mm 1 85 in 31 5 mm 1 2...

Страница 19: ...Minimum However note that installing the ATM in the minimum servicing area may increase the servicing and or upgrading time over a ATM installed using the optimum area Always leave as much space as p...

Страница 20: ...note that installing the ATM in the minimum servicing area may increase the servicing and or upgrading time over a ATM installed using the optimum area Always leave as much space as possible around t...

Страница 21: ...Maximum 110 mm 4 33 in 1080 mm 42 52 in 110 mm 4 33 in 770 mm 30 31 in 375 mm 14 76 in 2 3 175 mm 6 89 in 375 mm 14 76 in 1520 mm 59 84 in 2026 mm 79 76 in 2352 mm 92 60 in denotes small 10 volume in...

Страница 22: ...110 mm 4 33 in 70 mm 2 76 in 770 mm 30 31 in 2 1b 375 mm 14 76 in 2026 mm 79 76 in 326 mm 12 83 in 175 mm 6 89 in 2360 mm 92 91 in 110 mm 4 33 in 175 mm 6 89 in 450 mm 17 72 in 3 760 mm 29 92 in deno...

Отзывы: