background image

NCR

 

Proprietary

 

Information

 ‐ 

not

 

to

 

be

 

disclosed

 

or

 

reproduced

 

without

 

written

 

consent.

 

©

 

2017,

 

2018

 

by

 

NCR

 

Corporation,

 

Atlanta,

 

Georgia,

 

U.S.A.

 

http://www.ncr.com.All

 

Rights

 

Reserved

B006

7519

G000

Variant

 

Details

 ‐ 

CEN

 

I,

 

Standard

 

Collar

 

ATM

 

NCR

 

SelfServ™

 

84

 

Walk

Up

 

ATM

 

Site

 

Preparation

9

 ‐ 

2

FACIA

 

ITEMS

15”

 

Touchscreen

19”

 

Touchscreen

Touchscreen

 

Dimensions

Heights

 

and

 

Depths

Distance

 

for

 

Voice

 

Guidance

 

Touchscreen 
Size

Touchscreen 
Height x Width

Touchscreen 
Angle

15 inch

234 mm x 310 mm
9.21 in. x 12.20 in.

30 degrees from vertical

19 inch

305 mm x 380 mm
12.01 in. x 14.96 in.

30 degrees from vertical

5

JKL

S

$

1234 5678 9

1234 5678 9

S

S

5

JKL

S

Facia Item

Height from 

base of ATM

(4-High 

Dispenser Safe)

Height from 

base of ATM

(5-High 

Dispenser Safe)

Depth

from front

of shelf

Cheque Entry

1089 mm

(42.87 in.)

1207 mm

(47.52 in.)

218 mm

(8.58 in.)

Passbook Entry/Exit

1086 mm

(42.76 in.)

1204 mm

(47.40 in.)

218.5 mm

(8.60 in.)

Statement Exit

1084 mm

(42.68 in.)

1202 mm

(47.32 in.)

218 mm

(8.58 in.)

ID Scanner

1082 mm

(42.60 in.)

1200 mm

(47.24 in.)

236 mm

(9.29 in.)

Coin Exit

 1075 mm
(42.32 in.)

1193 mm

(46.97 in.)

234 mm

(9.21 in.)

Touchscreen - Top
483 mm (19.0 in.)

1074 mm

(42.28 in.)

1192 mm

(46.93 in.)

221 mm

(8.70 in.)

Receipt 

1031 mm

(40.59 in.)

1149 mm

(45.24 in.)

185 mm

(7.28 in.)

Touchscreen - Top
381 mm (15.0 in.)

1022 mm

(40.24 in.)

1140 mm

(44.88 in.)

191 mm

(7.52 in.)

Card Reader

915 mm

(36.02 in.)

1033 mm

(40.67 in.)

165 mm

(6.50 in.)

Contactless Card Reader (behind Facia)

915 mm

(36.02 in.)

1033 mm

(40.67 in.)

165 mm

(6.50 in.)

PIN Pad - Number 5 Key

849 mm

(33.43 in.)

967 mm

(38.07 in.)

136.5 mm

(5.37 in.)

Private Audio

780 mm

(30.71 in.)

898 mm

(35.35 in.)

59 mm

(2.32 in.)

Barcode Reader - Activation Point

757 mm

(29.80 in.)

875 mm

(34.45 in.)

33 mm

(1.30 in.)

Cash Exit/Entry

747 mm

(29.41 in.)

865 mm

(34.05 in.)

73 mm

(2.87 in.)

Scalable Deposit Module

747 mm

(29.41 in.)

865 mm

(34.05 in.)

73 mm

(2.87 in.)

$

5

JKL

S

1234 5678 9

No. 5 Key

Audio Jack

Facia Item

Distance to 

Facia Item

Distance to 

Facia Item

Receipt

1

193 mm

(7.60 in.)

1

277 mm

(10.91 in.)

Card Reader

2

86 mm

(3.39 in.)

1

169 mm

(6.65 in.)

Private Audio

6

100 mm

(3.94 in.)

-

-

Cash Exit/Entry

Right 
hand

7

127 mm

(5.00 in.)

7

65 mm

(2.56 in.)

Scalable Deposit Module

Right
hand

7

127 mm

(5.00 in.)

7

65 mm

(2.56 in.)

Barcode Reader - 
Activation Point

7

146 mm

(5.75 in.)

8

73 mm

(2.87 in.)

Scalable Deposit Module

Left
hand

8

354 mm

(13.94 in.)

9

73 mm

(2.87 in.)

Cash Exit/Entry

Left 
hand

8

354 mm

(13.94 in.)

9

73 mm

(2.87 in.)

Touchscreen
381 mm (15.0 in.)

Centre

10

284 mm

(11.18 in.)

10

329 mm

(12.95 in.)

Touchscreen
483 mm (19.0 in.)

Centre

10

290 mm

(11.42 in.)

10

341 mm

(13.43 in.)

Passbook Entry/Exit

10

314 mm

(12.36 in.)

10

396 mm

(15.59 in.)

Cheque Entry

10

481 mm

(18.82 in.)

10

545 mm

(21.46 in.)

ID Scanner

10

482 mm

(18.98 in.)

10

547 mm

(21.54 in.)

Contactless Card Reader 
(behind Facia)

11

77 mm

(3.03 in.)

11

171 mm

(6.73 in.)

Coin Exit

11

275 mm

(10.83 in.)

11

365 mm

(14.37 in.)

Statement Exit

11

312 mm

(12.28 in.)

11

395 mm

(15.55 in.)

12

11

10
9

8

7 6 5

4

3

2

1

12

11

10
9

8

7 6 5

4

3

2

1

S

1234 5678 9

1234 5678 9

S

$

Содержание SelfServ 84 Walk-Up

Страница 1: ...NCR SelfServ 84 Walk Up Standard Collar ATM Site Preparation B006 7519 G000...

Страница 2: ...NCR s copyright notice must be included It is the policy of NCR Corporation NCR to improve products as new technology components software and firmware become available NCR therefore reserves the right...

Страница 3: ...onths 5 2 Transit Range Up To One Week 5 2 Extreme Power On Range Up To One Hour 5 2 Barometric Pressure 5 2 Power Requirements AC Power Requirements 6 1 Input Voltage Setting 6 1 Grounding 6 1 Transi...

Страница 4: ...h page has two or three columns laid out as follows Where left and right side are stated the ATM is viewed from the front facia side of the ATM All plan views are from the top unless otherwise stated...

Страница 5: ...The responsibility for ensuring that the site is prepared in compliance with this document remains with the customer For information and guidance purposes only a list is provided in general terms of...

Страница 6: ...ds The ATM complies with the following requirements for radiated and conducted immunity EN 55024 1998 A1 2001 A2 2003 As per the requirements of EN55024 the ATM complies with the requirements of the f...

Страница 7: ...e with a medium to high feature functionality configuration Heat dissipation figures are largely unaffected by transactional rates PRODUCT IDENTIFICATION The illustration below is typical of the layou...

Страница 8: ...M can be found in the Variant Details sections DOORWAYS AND CORRIDORS Make sure that doorways and corridors leading to your point of installation are wide enough to allow the package to pass through o...

Страница 9: ...d humidity to a maximum humidity at 0 C 32 F Normal Operating Range Interior Environment Temperature 0 C to 40 C 32 F to 104 F Relative Humidity 20 to 80 Dew Point Temperature Restriction 26 C 79 F ma...

Страница 10: ...termittent short circuits and switching transients can be introduced on to power lines Such transient energy can be very damaging to electronic hardware and can also cause data corruption Under these...

Страница 11: ...ne of two options a basic alarm system or an enhanced alarm system A stabilised non interruptible power supply must be provided through the external alarm system The alarm interface cable wiring must...

Страница 12: ...rm to the following specification and wiring Remove a 20 mm 0 79 in section of the outer sleeve 100 mm 3 94 in from the ATM end of the cable Take care not to cut through the cable shielding ETHERNET S...

Страница 13: ...rif typeface should be used Tiresias is recommended The text size should be at least 14 point and larger where possible Where tactile decals are required they should be designed in line with specific...

Страница 14: ...7 in 770 mm 30 31 in 832 mm 32 76 in 664 mm 26 14 in 800 mm 31 50 in 801 mm 31 54 in 259 mm 10 20 in 226 mm 8 90 in 66 mm 2 60 in Note 1 60 mm 2 36 in 681 mm 26 81 in 502 mm 19 76 in 62 mm 2 44 in Not...

Страница 15: ...7 in 165 mm 6 50 in Contactless Card Reader behind Facia 915 mm 36 02 in 1033 mm 40 67 in 165 mm 6 50 in PIN Pad Number 5 Key 849 mm 33 43 in 967 mm 38 07 in 136 5 mm 5 37 in Private Audio 780 mm 30 7...

Страница 16: ...high tensile minimum ISO property class 8 8 Washers Type flat steel as per DIN7349 or equivalent Size M16 5 8 in Outer diameter no greater than 40 mm 1 58 in Minimum thickness 6 mm 0 2 in BOLT HOLES T...

Страница 17: ...mum 12 99 in 203 mm 330 mm 534 mm 21 02 in B 18 mm 0 71 in 625 mm 24 61 in A Hole in Wall ATM Base View from Inside Building Plinth Sidewalk increase to 635 mm 25 00 in if ATM installed with cash came...

Страница 18: ...hown assume the ATM is being moved using equipment that does not extend beyond the ATM or packaging A surrounding clearance of 6 mm 0 24 in has been allowed in the dimensions 47 mm 1 85 in 31 5 mm 1 2...

Страница 19: ...Minimum However note that installing the ATM in the minimum servicing area may increase the servicing and or upgrading time over a ATM installed using the optimum area Always leave as much space as p...

Страница 20: ...note that installing the ATM in the minimum servicing area may increase the servicing and or upgrading time over a ATM installed using the optimum area Always leave as much space as possible around t...

Страница 21: ...Maximum 110 mm 4 33 in 1080 mm 42 52 in 110 mm 4 33 in 770 mm 30 31 in 375 mm 14 76 in 2 3 175 mm 6 89 in 375 mm 14 76 in 1520 mm 59 84 in 2026 mm 79 76 in 2352 mm 92 60 in denotes small 10 volume in...

Страница 22: ...110 mm 4 33 in 70 mm 2 76 in 770 mm 30 31 in 2 1b 375 mm 14 76 in 2026 mm 79 76 in 326 mm 12 83 in 175 mm 6 89 in 2360 mm 92 91 in 110 mm 4 33 in 175 mm 6 89 in 450 mm 17 72 in 3 760 mm 29 92 in deno...

Отзывы: