background image

NCR

 

Proprietary

 

Information

 ‐ 

not

 

to

 

be

 

disclosed

 

or

 

reproduced

 

without

 

written

 

consent.

 

©

 

2017,

 

2018

 

by

 

NCR

 

Corporation,

 

Atlanta,

 

Georgia,

 

U.S.A.

 

http://www.ncr.com.All

 

Rights

 

Reserved

B006

7519

G000

 

NCR

 

SelfServ™

 

84

 

Walk

Up

 

ATM

 

Site

 

Preparation

8

 ‐ 

1

Decals

ADVERT

 

WINDOW

The

 

decals

 

should

 

be

 

a

 

maximum

 

of

 

0.75

 

mm

 

(0.0295

 

in.)

 

thick.

Advert

 

Collar

 

or

 

Open

 

Advert

 

Collar

ENTRY/EXIT

 

DECALS

Entry/Exit

 

decals

 

should

 

be

 

a

 

maximum

 

of

 

0.5

 

mm

 

(0.02

 

in.)

 

thick.

 

NCR

 

recommends

 

they

 

be

 

made

 

from

 

textured

 

polycarbonate

 

with

 

3M

 

467

 

High

 

Performance

 

MP

 

adhesive.

Decals

 

should

 

provide

 

good

 

contrast,

 

at

 

least

 

70%,

 

between

 

foreground

 

(text/

icon)

 

and

 

background.

 

A

 

sans

 

serif

 

typeface

 

should

 

be

 

used

 

(Tiresias

 

is

 

recommended).

 

The

 

text

 

size

 

should

 

be

 

at

 

least

 

14

 

point,

 

and

 

larger

 

where

 

possible.

 

Where

 

tactile

 

decals

 

are

 

required

 

they

 

should

 

be

 

designed

 

in

 

line

 

with

 

specific

 

country

 

requirements.

Suggested

 

icon

 

designs

 

and

 

wording

 

are

 

shown

 

below:

CAUTION

When

 

placing

 

any

 

card

 

reader

 

decal,

 

make

 

sure

 

that

 

the

 

label

 

does

 

not

 

obscure

 

the

 

contactless

 

card

 

reader

 

or

 

card

 

reader

 

entry

 

slot

 

lights.

CAUTION

Do

 

NOT

 

place

 

any

 

metallic

 

coated

 

or

 

substrate

 

label

 

on

 

the

 

glass

 

area

 

around

 

the

 

CCR

 

or

 

card

 

reader,

 

highlighted

 

below:

595.5 mm

(23.44 in.)

2.5 mm

(0.10 in.)

Radius in

four corners

160 mm

(6.30 in.)

Cash Deposit

Cash Dispense

Receipt

Cash

Dispense/Deposit

Cheque Deposit

1234 5678 9

Coin Dispense

Statement

Cash/Cheque

Deposit

1234 5678 9

Statement and
Passbook Printer

Passbook Printer

12 mm

(0.47 in.)

75 mm

(2.95 in.)

Содержание SelfServ 84 Walk-Up

Страница 1: ...NCR SelfServ 84 Walk Up Standard Collar ATM Site Preparation B006 7519 G000...

Страница 2: ...NCR s copyright notice must be included It is the policy of NCR Corporation NCR to improve products as new technology components software and firmware become available NCR therefore reserves the right...

Страница 3: ...onths 5 2 Transit Range Up To One Week 5 2 Extreme Power On Range Up To One Hour 5 2 Barometric Pressure 5 2 Power Requirements AC Power Requirements 6 1 Input Voltage Setting 6 1 Grounding 6 1 Transi...

Страница 4: ...h page has two or three columns laid out as follows Where left and right side are stated the ATM is viewed from the front facia side of the ATM All plan views are from the top unless otherwise stated...

Страница 5: ...The responsibility for ensuring that the site is prepared in compliance with this document remains with the customer For information and guidance purposes only a list is provided in general terms of...

Страница 6: ...ds The ATM complies with the following requirements for radiated and conducted immunity EN 55024 1998 A1 2001 A2 2003 As per the requirements of EN55024 the ATM complies with the requirements of the f...

Страница 7: ...e with a medium to high feature functionality configuration Heat dissipation figures are largely unaffected by transactional rates PRODUCT IDENTIFICATION The illustration below is typical of the layou...

Страница 8: ...M can be found in the Variant Details sections DOORWAYS AND CORRIDORS Make sure that doorways and corridors leading to your point of installation are wide enough to allow the package to pass through o...

Страница 9: ...d humidity to a maximum humidity at 0 C 32 F Normal Operating Range Interior Environment Temperature 0 C to 40 C 32 F to 104 F Relative Humidity 20 to 80 Dew Point Temperature Restriction 26 C 79 F ma...

Страница 10: ...termittent short circuits and switching transients can be introduced on to power lines Such transient energy can be very damaging to electronic hardware and can also cause data corruption Under these...

Страница 11: ...ne of two options a basic alarm system or an enhanced alarm system A stabilised non interruptible power supply must be provided through the external alarm system The alarm interface cable wiring must...

Страница 12: ...rm to the following specification and wiring Remove a 20 mm 0 79 in section of the outer sleeve 100 mm 3 94 in from the ATM end of the cable Take care not to cut through the cable shielding ETHERNET S...

Страница 13: ...rif typeface should be used Tiresias is recommended The text size should be at least 14 point and larger where possible Where tactile decals are required they should be designed in line with specific...

Страница 14: ...7 in 770 mm 30 31 in 832 mm 32 76 in 664 mm 26 14 in 800 mm 31 50 in 801 mm 31 54 in 259 mm 10 20 in 226 mm 8 90 in 66 mm 2 60 in Note 1 60 mm 2 36 in 681 mm 26 81 in 502 mm 19 76 in 62 mm 2 44 in Not...

Страница 15: ...7 in 165 mm 6 50 in Contactless Card Reader behind Facia 915 mm 36 02 in 1033 mm 40 67 in 165 mm 6 50 in PIN Pad Number 5 Key 849 mm 33 43 in 967 mm 38 07 in 136 5 mm 5 37 in Private Audio 780 mm 30 7...

Страница 16: ...high tensile minimum ISO property class 8 8 Washers Type flat steel as per DIN7349 or equivalent Size M16 5 8 in Outer diameter no greater than 40 mm 1 58 in Minimum thickness 6 mm 0 2 in BOLT HOLES T...

Страница 17: ...mum 12 99 in 203 mm 330 mm 534 mm 21 02 in B 18 mm 0 71 in 625 mm 24 61 in A Hole in Wall ATM Base View from Inside Building Plinth Sidewalk increase to 635 mm 25 00 in if ATM installed with cash came...

Страница 18: ...hown assume the ATM is being moved using equipment that does not extend beyond the ATM or packaging A surrounding clearance of 6 mm 0 24 in has been allowed in the dimensions 47 mm 1 85 in 31 5 mm 1 2...

Страница 19: ...Minimum However note that installing the ATM in the minimum servicing area may increase the servicing and or upgrading time over a ATM installed using the optimum area Always leave as much space as p...

Страница 20: ...note that installing the ATM in the minimum servicing area may increase the servicing and or upgrading time over a ATM installed using the optimum area Always leave as much space as possible around t...

Страница 21: ...Maximum 110 mm 4 33 in 1080 mm 42 52 in 110 mm 4 33 in 770 mm 30 31 in 375 mm 14 76 in 2 3 175 mm 6 89 in 375 mm 14 76 in 1520 mm 59 84 in 2026 mm 79 76 in 2352 mm 92 60 in denotes small 10 volume in...

Страница 22: ...110 mm 4 33 in 70 mm 2 76 in 770 mm 30 31 in 2 1b 375 mm 14 76 in 2026 mm 79 76 in 326 mm 12 83 in 175 mm 6 89 in 2360 mm 92 91 in 110 mm 4 33 in 175 mm 6 89 in 450 mm 17 72 in 3 760 mm 29 92 in deno...

Отзывы: