Transferring Files To and From a Remote Location
2-42
MP-RAS Remote Support
Option
Values
Description
-b
300, 1200, 2400,
4800, 9600, 19200,
38400, 57600,
115200
Baud rate
Note: The file transfer baud rate must be the
same as the console redirection baud rate.
Only 9600, 19.2K, and 38.4K are
recommended.
-f
<directory name>
Name of the directory in which the file
transfer configuration file (
ft.cfg) is located
Note: The default setting is the directory
containing the sf executable file. This is the
\REMOTE directory on your server.
-h
Display online help text.
-l
<filename>
File containing a list of files to send. (You
might want to create such a file if you
frequently send the same files.)
Note: The specified file should be an ASCII
file containing one filename per line.
-p
1, 2
Server COM port to use for file transfer
Note: The COM port must be the same as
the console redirection port.
-r
Do not reboot server after sending files
-s
x - XON/XOFF
r - RTS/CTS
n - none
Type of flow control to use
Note: The flow control setting must be the
same as the console redirection flow control
setting.
Содержание S46
Страница 1: ...B003 0145 A 6 97 NCR S46 Server MP RAS Support Guide Release 1...
Страница 6: ...Contents iv Contents...
Страница 10: ...Preface viii Preface...
Страница 11: ...NCR S46 Server MP RAS Support Guide 1 1 Chapter 1 Installing MP RAS...
Страница 32: ...Restoring MP RAS 1 22 Installing MP RAS...
Страница 33: ...NCR S46 Server MP RAS Support Guide 2 1 Chapter 2 MP RAS Remote Support...
Страница 88: ...Using the Server Monitor Module for Remote Management 2 56 MP RAS Remote Support...