130 Appendixes
d. At high fire, do not check the offset value
and never adjust the gas valve.
DANGER
Improper gas valve settings can cause severe
personal injury, death or substantial property
damage.
13. Once the CO
2
or offset values have been
confirmed, apply the included conversion
stickers to show that the appliance has been
converted to Propane Gas or High Altitude.
Place these labels adjacent to the rating plate as
shown in Figure 11.
with Kit No. ________________________
This boiler was converted on
(name and address of organization making
this conversion, who accepts responsibility
for the correctness of this conversion)
______/______/______ to ____________ gas
by _________________________________
_________________________________
Figure 11. Proper Placement of Propane Gas or
High Altitude Conversion Labels
Note
The Propane Gas or High Altitude
conversion rating plate varies
depending on the model. Check
the conversion kit number before
attaching the labels.
Содержание NCB-190/060H
Страница 137: ...137 Appendixes 12 6 2 Burner Assembly 12 13 10 20 21 11 7 3 1 2 5 24 6 9 23 22 8 14 19 16 17 10 15 18 4...
Страница 141: ...141 Appendixes 12 6 4 Fan Gas Assembly 10 9 12 8 7 3 1 2 4 5 6 13 11 11 14 15...
Страница 143: ...Memo...