104 Operating the Boiler
11.4.2 Adjusting the DHW Temperature
To adjust the water temperature:
1. In normal operation mode, rotate the Command
dial (
). The space heating temperature ( ) is
highlighted on the screen.
2. Rotate the Command dial (
) to the right to
select the DHW temperature.
3. Press the Command dial (
) to select the DHW
temperature (
). The highlighted section will
flash.
4. Rotate the Command dial (
) to the right or
left to increase or decrease the temperature.
2. Press the Command dial (
) to select the space
heating temperature. The highlighted section
will flash.
3. Rotate the Command dial (
) to the right or
left to increase or decrease the temperature.
4. Press the Command dial (
) to confirm the
new temperature.
5. Press the Back button (
) to return to normal
operation mode, or rotate the Command dial
(
) to adjust other operation conditions.
You can adjust the temperature while the
highlighted section is flashing. Once the flashing
stops, the current temperature setting is stored.
Note
●
The space heating temperature
cannot be adjusted when the Outdoor
Reset Control is used.
●
In case of outdoor reset sensor
malfunction, the boiler will operate at
this set temperature.
●
Take note of the original heating
temperature in case you want to
restore it to the default.
●
The default space heating supply
water temperature range is 104°F
(40°C, Absolute MIN) to 180°F (82°C,
Absolute MAX).
●
The default space heating return
water temperature range is 86°F
(30°C, Absolute MIN) to 149°F (65°C,
Absolute MAX).
●
You can adjust the temperature ranges
in the parameter settings menu.
●
The boiler will retain your settings
during a power outage.
Содержание NCB-190/060H
Страница 137: ...137 Appendixes 12 6 2 Burner Assembly 12 13 10 20 21 11 7 3 1 2 5 24 6 9 23 22 8 14 19 16 17 10 15 18 4...
Страница 141: ...141 Appendixes 12 6 4 Fan Gas Assembly 10 9 12 8 7 3 1 2 4 5 6 13 11 11 14 15...
Страница 143: ...Memo...
Страница 144: ......