PN6280_Hardware Design
Copyright © JSC NIIMA PROGRESS and NAVIA LLC
34
6. Storage and Production
6.1 Storage
The rank of moisture proof of the module is level 3. There is an obvious sign on the table of the internal
and the external packaging.
In the vacuum sealed bag, the module can be stored for 180 days when the temperature is below
40
°C and the humidity is below 90% under good air circulation.
Humidity level is descripted detail as follows:
Table 6-1 Humidity level
Rank
Factory Environment
≦
+30°C /60%RH
1
No controll < 30°C /85%RH
2
One year
2a
4 weeks
3
168 hours
4
72 hours
5
48 hours
5a
24 hours
6
Baking before using, SMT during the time table signs
Notes: Moving, storage, production of module must meet the demand of IPC/JEDEC J-STD-033.
6.2 Production
The module is a humidity sensitive device. If the device needs reflow soldering, disassembly and
maintenance, we must strictly comply with the requirements of humidity sensitive device. If module is