![Nautel NX5 AM Скачать руководство пользователя страница 213](http://html1.mh-extra.com/html/nautel/nx5-am/nx5-am_operation-and-maintenance-manual_711218213.webp)
NX5 OPERATION & MAINTENANCE MANUAL
ROUTINE MAINTENANCE
VERSION 0.1 2015-08-01
PAGE 3.3.9
Replacing the Control/Interface PWB Battery
Replace the battery on the control/interface PWB once a year, or whenever the
Controller - Low
Battery
alarm appears (on the front panel UI, remote AUI or via digital output). Chemical leakage from
an old battery can cause damage. Also, the control/interface PWB’s microcontroller may not retain its
settings if ac power is turned off while the backup battery power is low. The battery should be replaced
while ac power is applied to the transmitter.
Interval
Every 12 months.
Parts and Tools
Replacement battery. 3 V lithium coin cell, 20 mm (Nautel Part # BBLT01, Panasonic # Panasonic
CR2032).
Procedure
Perform the following steps to replace the battery:
1.
Ensure ac power is being applied to the transmitter.
2.
Open the front door to access the control/interface PWB (A4), which is located on the exciter panel
(see
3.
Replace the battery in XBT1 on the control/interface PWB (A4).
4.
Close the front door.
5.
Check for any alarms on the front panel UI or the remote AUI.
Содержание NX5 AM