![Nautel NX5 AM Скачать руководство пользователя страница 185](http://html1.mh-extra.com/html/nautel/nx5-am/nx5-am_operation-and-maintenance-manual_711218185.webp)
NX5 OPERATION & MAINTENANCE MANUAL
OPERATING THE TRANSMITTER
VERSION 0.1 2015-08-01
PAGE 3.2.165
–
Scheduler On/Off
- enables/disables the automatic mode scheduler.
–
Max Power Lockout 1 - 8
- selects the associated power lockout limit (1 - 8) as active (functions
regardless of local/remote mode).
–
Preset:
(name) - selects the appropriate operating preset as active.
3.
The
Level
bar displays the input’s current logic level (1 or 0).
4.
Configure the active/inactive control for each of the 10 digital inputs. Click the arrow beside the
Control
bar to display the following drop-down menu options:
–
Rising Edge, Turn On/Reboot/Set To A/Set To B
. Logic ‘1’ (high or rising edge) activates the
input (or causes a reset, as appropriate).
–
Falling Edge, Turn On/Reboot/Set To A/Set To B
. Logic ‘0’ (low or trailing edge) activates the
input (or causes a reset, as appropriate).
–
Rising Edge, Turn Off
. Logic ‘1’ (high or rising edge) de-activates the input.
–
Falling Edge, Turn Off
. Logic ‘0’ (low or trailing edge) de-activates the input.
–
Falling Edge, Toggle
. Logic ‘0’ (low or trailing edge) de-activates the input; next logic ‘0’ (low or trailing
edge) activates the input.
–
Rising Edge, Toggle
. Logic ‘1’ (high or rising edge) activates the input; next logic ‘1’ (high or rising
edge) de-activates the input.
–
Rising Edge, Turn On/Set To B. Falling Edge Turn Off/Set To A
. Logic ‘1’ (high or rising edge)
activates the input; logic ‘0’ (low or trailing edge) de-activates the input.
–
Falling Edge, Turn On/Set To B. Rising Edge Turn Off/Set to A
. Logic ‘0’ (low or trailing edge)
activates the input; logic ‘1’ (high or rising edge) de-activates the input.
–
Active High, Increase
. Logic ‘1’ (high) causes a power increase or turns on the feature.
–
Active Low, Increase
. Logic ‘0’ (low) causes a power increase.
–
Active High, Decrease
. Logic ‘1’ (high) causes a power decrease.
–
Active Low, Decrease
. Logic ‘0’ (low) causes a power decrease.
–
Active High, Turn On
. Logic ‘1’ (high) activates the input.
–
Active Low, Turn On
. Logic ‘0’ (low) activates the input.
5.
When the input settings are complete, click
Apply
to accept and activate these changes or click
Cancel
to cancel them and return to the previous settings.
6.
To exit the page, click
X
(top right).
NOTE:
If you save a change to a digital input via the remote AUI, it will also be displayed on the front