Analog Outputs - Front Panel UI
Using the
Analog Outputs
screens (see
Figure 3.2.157 on page 3.2.172
), you can view the levels of
four pre-defined analog outputs that are representative of critical transmitter parameters - forward
power, reflected power, B+ voltage and total dc current.
Nautel sets analog output defaults prior to shipping. There are no configuration options. They are for
monitoring purposes only. See the NX5 Pre-installation Manual for details.
Figure 3.2.157: Analog Outputs Screens
Use the up and down buttons to select the desired analog output (1 through 4) from the list. Press
cancel (
X
) to return to the previous menu. Each screen shows:
Line 1: displays the analog output parameter (e.g., 1: Forward Pwr, 2: Refl Power, B+ Sample
or Total DC Current) and its voltage relationship to the actual unit of measure [i.e. square law
(sq) or linear (lin)].
Line 2: displays the actual meter reading and the full-scale reading
Line 3: displays the actual output pin voltage and the full-scale voltage (6.00 V).
NOTE
: The analog output’s
Output
voltage reading reflects the value that can be measured at the
associated remote analog output pin for the given
Meter
value. See the Pre-installation Manual for
actual remote analog output pin assignments.