![Nautel NX5 AM Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/nautel/nx5-am/nx5-am_operation-and-maintenance-manual_711218010.webp)
NX5 OPERATION & MAINTENANCE MANUAL
DESCRIPTION
PAGE 3.1.2
VERSION 0.1 2015-08-01
Ac-Dc Power Stage
and electrical schematic
SD-1
. The ac/dc power supply stage contains
the input power transformer that receives the main ac input to the transmitter. It also contains the
transmitter’s low voltage power supplies and rack interface PWB. The ac/dc power supply stage also
includes a three-phase SCR rectifier assembly, B+ current sensor, B+ distribution assembly and arc
detector assembly.
Ac Power Transformer
The NX5’s power transformer can be set to use a range of input voltages. See
in the
NX5 Installation Manual
.
High Voltage B+ Supply
The secondary of the power transformer is applied to the SCR rectifier assembly to create the
transmitter’s B+ voltage. The output of the rectifier assembly is fed through the B+ current sensor,
which supplies a B+ current sample to the rack interface PWB. The rectifier assembly output is applied
to a choke input filter and the B+ distribution assembly, which then provides the B+ voltage to the RF
power modules.
The B+ discharge relay, which is part of the B+ distribution assembly, opens when ac power is applied
and closes and ac power is removed, applying a high power discharge resistor across the B+ bus to
quickly discharge the voltage. When the discharge relay closes, a microswitch ensures the SCR rectifier
is immediately inhibited.
Low Voltage Power Supplies
One phase of the power transformer’s secondary is also used to provide a source for the low voltage dc
power supplies and an ac sample for the rack interface PWB. The low voltage power supply outputs
(+48 V and +15 V) are distributed throughout the transmitter via the rack interface PWB. The +48 V
power supply sources the transmitter’s cooling fans. An inhibit signal, controlled by the rack interface
PWB, is applied to the +48 V power supply to turn the fans on and off. The +15 V power supply sources
all of the low voltage control circuitry.