![Nautel NX5 AM Скачать руководство пользователя страница 151](http://html1.mh-extra.com/html/nautel/nx5-am/nx5-am_operation-and-maintenance-manual_711218151.webp)
NX5 OPERATION & MAINTENANCE MANUAL
OPERATING THE TRANSMITTER
VERSION 0.1 2015-08-01
PAGE 3.2.131
RF Monitor Level
The
RF Monitor Level
page allows you to set values for the
Gain at Full Power
(in dB) (see
) on the amplifier that drives the
RF Monitor
output. The RF monitor is factory set to
provide a level of 5 V rms into 50 ohm (27 dBm).
The
Current Gain
value is shown for reference. Increase the gain to increase the RF monitor output
level; decrease the gain to decrease the RF monitor output level. The transmitter will attempt to
maintain this level at all power set points:
Figure 3.2.112: System Settings - RF Monitor Level
Procedure to set the RF monitor level:
1.
Select the
RF Monitor Level
option from the left side of the
System Settings
page to open a
related window on the right side of the page.
2.
Observe the
Current Gain
value and its corresponding RF monitor level (measured). Enter the new
Gain at Full Power
value to increase or decrease the RF monitor level.
3.
Click
Apply
. Verify the measured RF monitor level is as desired. Readjust as necessary.