NX15/NX25 Operations and Maintenance Manual
Operating the transmitter
Issue 6.0 2019-01-31
Page 2-31
Use the left and right buttons to make fine adjustments.
Use the up or down button to maximize (if it was minimized) or minimize (if it was
maximized) the panel size.
Use the “peak” button to place the cursor on the next successive peak (moving left to right) in
the spectrum.
Use the “cog” button to gain access to spectrum settings (see
) such as:
•
Resolution Bandwidth:
determines the FFT bin size or the smallest frequency that can
be resolved. Set between 90 Hz and 2500 Hz (default is 300 Hz). Decreasing this value
provides better frequency resolution, but will increase the sweep time.
•
Span
: determines the start and stop frequencies of the analyzer with the carrier fre-
quency always at the center. Set between 20 kHz and 300 kHz (default is 150 kHz).
•
Averages
: determines the number of averages that the analyzer performs per sweep. Set
between 0 and 100 (default is 19).
•
Measurement Source
: determines the source of the spectrum plot (transmitter output,
audio analyzer, etc.) that is being displayed. Selecting
TX Output
uses the exciter’s RF
sample feedback signal to display the RF output spectrum. Selecting
Audio Analyzer
displays the composite baseband signal.
•
Clear Averaging:
resets the averaged signal shown on the spectrum analyzer.
Figure 2.16: Spectrum Settings
Содержание NX15
Страница 2: ......
Страница 4: ......
Страница 8: ...NX15 NX25 Operations and Maintenance Manual Page viii Issue 6 0 2019 01 31...
Страница 22: ...NX15 NX25 Operations and Maintenance Manual Description Page 1 14 Issue 6 0 2019 01 31...
Страница 24: ...NX15 NX25 Operations and Maintenance Manual Page 1 12 Issue 6 0 2019 01 31 This page left bla...
Страница 30: ......
Страница 168: ...NX15 NX25 Operations and Maintenance Manual Routine maintenance Page 3 8 Issue 6 0 2019 01 31...
Страница 177: ......