NX15/NX25 Operations and Maintenance Manual
Operating the transmitter
Page 2-30
Issue 6.0 2019-01-31
Figure 2.15: Spectrum Analyzer
Spectrum analyzer.
See
. The carrier level is normalized to its unmodulated level
at 0 dB. The graph center is always at the carrier frequency, as defined by the Exciter’s set
Frequency value.
Masks are shown based on transmission mode and are defined by the following standards:
• Analog AM standard: NRSC-2-B
• DRM and DRM+AM standards: ITU-R SM.328-11 and ITU-R SM.1541-4
• IBOC and IBOC+AM: NRSC-5-C
NOTE:
Any spurious emissions that are displayed are a product of the spectrum analyzer and are
not actually present on the transmitter output.
Touch on the panel to display a cursor on the trace in the approximate area. The cursor
position (frequency and amplitude) is shown in the upper, right-hand corner of the panel. The
center frequency is shown in the upper, left-hand corner of the panel. Touch in other areas of
the spectrum analyzer panel to provide a coarse adjustment of the cursor position.
Peak
Cog
Cursor
Left
Cursor
Right
Close
Minimize
(Maximize)