NX15/NX25 Operations and Maintenance Manual
Routine maintenance
Page 3-6
Issue 6.0 2019-01-31
Replacing the Control/Interface PWB battery
Replace the battery on the Control/Interface PWB once a year, or whenever the
Controller -
Low Battery
alarm appears (on the AUI or via digital output). Chemical leakage from an old
battery can cause damage. Also, the Control/Interface PWB’s microcontroller may not retain
its settings if ac power is turned off while the backup battery power is low. The battery should
be replaced while ac power is applied to the transmitter.
Interval
Every 12 months.
Parts and tools
Replacement battery. 3 V lithium coin cell, 20 mm (Nautel recommends Panasonic Part #
CR2032).
Procedure
Perform the following steps to replace the battery:
1. Ensure ac power is being applied to the transmitter.
2. Open the front door of the control cabinet (A1).
3. Replace the battery in XBT1 on the control/interface PWB, noting the control/
interface PWB is located on the control/exciter panel (A1A11) behind the front door.
See Figures MD-5 and MD-6 in the Mechanical Drawings section at the end of the
Troubleshooting manual
.
4. Close the front door.
5. Check for any alarms on the AUI. (See
Содержание NX15
Страница 2: ......
Страница 4: ......
Страница 8: ...NX15 NX25 Operations and Maintenance Manual Page viii Issue 6 0 2019 01 31...
Страница 22: ...NX15 NX25 Operations and Maintenance Manual Description Page 1 14 Issue 6 0 2019 01 31...
Страница 24: ...NX15 NX25 Operations and Maintenance Manual Page 1 12 Issue 6 0 2019 01 31 This page left bla...
Страница 30: ......
Страница 168: ...NX15 NX25 Operations and Maintenance Manual Routine maintenance Page 3 8 Issue 6 0 2019 01 31...
Страница 177: ......