NX15/NX25 Operations and Maintenance Manual
Description
Issue 6.0 2019-01-31
Page 1-3
Rack Interface PWB
The rack interface PWB provides various functions for the ac-dc power stage, including:
• Monitors the B+ voltage and regulates the SCR rectifier’s output via the B+ level
control signal applied to the rectifier’s SCR control board.
• Monitors the SCR rectifier’s fan speeds, temperature and phase loss indication as well
as the B+ current sample and provides this information, along with data received over
a serial bus from the RF power modules, to the transmitter controller.
• Monitors the arc detector assembly.
• Generates the +30 V dc supply used by the SCR rectifier’s controller and the -15 V dc
supply used by the Hall Effect B+ current sensor.
• Generates the +5V dc supply used by control logic throughout the transmitter.
• Accepts the +48V from the +48V power supply and distributes it to the fans and
power module interface PWBs.
• Accepts the fan tach signal from each fan in the RF Power Stage and distributes them
to the power module interface PWBs.