Maximum on-state voltage drop ............................1.2 V at 100 mA
Reverse polarity protection ....................................Yes, –30 V
Short circuit and overload protection.....................Yes
General Purpose Digital Outputs
Type........................................................................Optically isolated, current sourcing
Output voltage range..............................................5 to 30 V
Output current
5 V
iso
..............................................................60 mA, maximum
24 V
iso
............................................................150 mA, maximum
30 V
iso
............................................................160 mA, maximum
Maximum pulse rate ..............................................10 KHz
Minimum pulse generated .....................................100 µs
Maximum on-state voltage drop ............................1.2 V at 100 mA
Reverse polarity protection ....................................Yes, –30 V
Short circuit and overload protection.....................Yes
Step/Direction/Breakpoint Outputs
Compatibility .........................................................Signal pass-through
Analog Inputs
Compatibility .........................................................Signal pass-through
Analog Outputs
Compatibility .........................................................Signal pass-through
Host Bus Voltage Interlock
Voltage ...................................................................4.2 VDC
Power Characteristics
Input voltage range ................................................24 V ± 10%, 0.20 Amps
V
iso
power source ...................................................5 to 30 VDC, 1.75 Amps
Environmental Conditions
Operating temperature ...........................................0 to 55 °C
Storage temperature ...............................................–30 to 80 °C
Humidity ................................................................10 to 90% RH, noncondensing
Pollution Degree (IEC 60664) ...............................2
Maximum altitude..................................................2,000 m
Indoor use only.