To ensure accurate performance and protection, avoid mechanical shock

to the probe. Do not bend or pull the probe cable.

Due to the nature of open probes, there may be susceptibility to outside

interference.

When to Calibrate the SA1000X

The first time the SA1000X requires user calibration depends on how much time has

elapsed between its factory calibration and the first time you use the probe.

Complete the following steps to determine when you need to perform your first

calibration of the SA1000X.

1. Refer to Date Calibrated on the calibration certificate included in your kit.

This is the date of the probe's factory calibration.

2. Compare the date you are first using the probe to the date of the factory

calibration, and perform your initial calibration as follows:

First-Time Use of Probe

When to Calibrate

<1 year after factory calibration

No more than one year after first-time use

≥1 year, <2 years after factory calibration

No more than two years after factory calibration

≥2 years after factory calibration

Before first-time use

Once you have determined the next calibration date, mark the date on the sticker

supplied with the probe and apply the sticker to the side of the probe. Perform

subsequent calibrations of the SA1000X at one-year intervals.

Related concepts

Calibration

© National Instruments

7

SA1000X Safety, Environmental, and Regulatory Information

Содержание SA1000X

Страница 1: ...SA1000X Safety Environmental and Regulatory Information 2022 07 08...

Страница 2: ...Contents About the SA1000X 3 ni com 2 SA1000X Safety Environmental and Regulatory Information...

Страница 3: ...in G e r m a n y S A 1 5 0 0 X Caution Observe all instructions and cautions in the user documentation Using the model in a manner not specified can damage the model and compromise the built in safety...

Страница 4: ...system for any functional purpose other than safety Getting Started Verifying the Kit Contents Calibration certificate Calibration date sticker Ground blade Ground lead 6 cm Ground lead 12 cm Ground l...

Страница 5: ...ons la terre Assurez vous toujours que la sonde et l instrument de mesure sont correctement mis la terre Caution Connect the probe output to the measurement instrument and connect the ground lead to e...

Страница 6: ...nces Using the Probe Operating Basics The SA1000X is system independent its standard BNC connector can be plugged into any measuring instrument with a 50 input The SA1000X is suitable for measurements...

Страница 7: ...is is the date of the probe s factory calibration 2 Compare the date you are first using the probe to the date of the factory calibration and perform your initial calibration as follows First Time Use...

Страница 8: ...warmed up for at least 30 minutes Environmental conditions within the probe s specified limits Electrical Specifications Attenuation ratio 10 1 0 5 DC Dynamic measuring range 8 V Bandwidth probe only...

Страница 9: ...ical Input Impedance Input impedance decreases as the frequency of the applied signal increases 1 1 k 10 k 100 k 1 M Z Ohm 1 10 10 k 1 k 100 100 M 10 M 1 M 100 k 1 G Frequency Hz Electrical Characteri...

Страница 10: ...to signals or use for measurements within Measurement Categories II III or IV Attention Ne connectez pas le SA1000X des signaux et ne l utilisez pas pour effectuer des mesures dans les cat gories de...

Страница 11: ...for direct connection to the MAINS building installations of Measurement Categories CAT II CAT III or CAT IV Related reference Electrical Specifications Environmental Characteristics Temperature and...

Страница 12: ...tion on contacting NI Related tasks When to Calibrate the SA1000X Related reference Electrical Specifications Test Equipment Refer to Table 1 and Table 2 for a list of necessary equipment and where ap...

Страница 13: ...e Verifying DC Accuracy Impedance 50 2 4 mm double banana m to BNC f adapter Verifying DC Accuracy 2 Verifying Zero Offset 1 Impedance 50 BNC feed through terminator Verifying DC Accuracy Verifying Ze...

Страница 14: ...plete the following to verify that the performance of your SA1000X is within specification Verifying DC Accuracy Verifying Zero Offset Required Software for Calibration NI DMM PXIe 4082 first supporte...

Страница 15: ...AWG PXIe 4082 6 Digit DMM 5 6 6 10 3 4 1 2 3 7 8 9 1 SA1000X 2 SMA f to probe tip adapter 3 BNC m to SMA m adapter 4 BNC f f f tee 5 BNC m to BNC m cable 6 Double banana m to BNC f adapter 7 BNC feed...

Страница 16: ...ignal from the DC source 5 Measure the 5 V signal with DMM 1 measure the output of the probe with DMM 2 6 Calculate the following ReadingDMM 1 10 ReadingDMM 2 7 Verify that the result is 500 V If the...

Страница 17: ...r at least 30 minutes 3 Configure the DMM with the following settings Function DC voltage Resolution 6 5 digits Number of Averages 4 Auto Zero Enabled Range 100 mV 4 Measure the signal at the DMM 5 Ve...

Страница 18: ...ni com environment This page contains the environmental regulations and directives with which NI complies as well as other environmental information not included in this document EU and UK Customers...

Страница 19: ...the appropriate link NI Services Visit ni com support to find support resources including documentation downloads and troubleshooting and application development self help such as tutorials and exampl...

Отзывы: