Code
(hex)
Additional code
Meaning
Remedy
0A51
—
A frame reference from 1 to 254 is
permitted only.
Currently, the value 1 is
permitted only.
0A54
—
The maximum number of I/O
points was exceeded.
Reduce the number of
I/O points to the
maximum number. To
obtain the exact number,
please refer to the
documentation for your
controller.
0A60
—
No configuration frames could be
assigned.
Create the configuration
frame.
0A70
—
A reserved bit has been set in the
Diag_Info attribute.
Check the parameters.
0A73
Device number
Device present with a chip version
in the local bus that is not
supported.
Replace the device.
0A74
Device number
Device of a manufacturer that is
not supported present in the local
bus.
Replace the device.
0A75
Device number
Device is indicating a serious
error (e. g., faulty EEPROM).
Restart the device.
Contact NI if the
problem persists.
0A76
Device number
The topology used by the device
is not supported by the master.
Replace the device.
0A77
Device number
Error at the interface.
Check the connection
between the electronics
module and bus base
module.
0A7 A
—
Invalid Dev_Type specified
during loading.
Check the parameters.
0A7B
—
Invalid Dev_ID specified during
loading.
Check the parameters.
16
|
ni.com
|
REM-11180 User Manual