background image

Code

(hex)

Meaning

Text

Remedy

 

 

 

 

6301

Device error

CS FLASH

Restart the device. Replace the
device if the error still occurs.

6302

Device error

FO FLASH

6320

Parameter table invalid

Invalid para

Check the parameterization of
the specified device.

7300

Encoder error

Sensor/encoder fail Check the encoder.

7305

Encoder error

Malfunction of
encoder

Check the encoder.

7610

Receive buffer full

Rx-Buf full

Read the receive buffer.

7611

Transmit buffer full

Tx-Buf full

Check the handshake.

7620

EPROM (device error)

CS ROM

Restart the device. Replace the
device if the error still occurs.

7710

Open circuit at sensor
cable

Remove the open circuit.

Open circuit

Open circuit

8600

Input error of
incremental encoder

Encoder input
signal error

Check the input signal.

Remove the short circuit.

Connect the sensor.

8910

Overrange

Overrange

Adapt the range.

Check the wiring.

8920

Underrange

Underrange

22

  | 

ni.com

  | 

REM-11180 User Manual

Содержание REM-11180

Страница 1: ...rt Reset Button Local Bus Ubus Power Supply Microcontroller UL 24 V GND RJ45 RJ45 Isolation Contents REM 11180 Features 2 Ports and Connectors 3 Reset Button 4 LEDs 5 Dimensions 8 Configuring the Rota...

Страница 2: ...Features The REM 11180 provides the following features Figure 1 Structure of the REM 11180 S 1 S 2 1 4 5 7 6 2 3 1 Bus connector 2 REM 11180 3 Ethernet connectors 4 Module function label 5 Supply vol...

Страница 3: ...rnet Ports 2 1 1 Ethernet In 2 Ethernet Out Table 1 RJ 45 Ethernet Port Pinout Fast Ethernet Signal Pin Pinout TXD 1 1 2 3 4 5 6 7 8 TXD 2 RXD 3 Reserved 4 Reserved 5 RXD 6 Reserved 7 Reserved 8 Figur...

Страница 4: ...umpered Figure 4 Service Interface 2 1 1 Label 2 Service Interface Note The service interface is a micro USB port used for factory service and configuration You do not need to connect to this port for...

Страница 5: ...t present Figure 7 Status LEDs RUN ERR RDY D E Table 4 Status LED Indicators LED LED Color LED Pattern Indication RUN Off Bus coupler in Init state Green Flashing slowly 2 5 Hz Bus coupler in Pre Oper...

Страница 6: ...ms off 200 ms on 1000 ms off watchdog timeout Solid Critical internal error RDY Green Solid Device is ready for operation Green Yellow Flashing Communications power undervoltage or surge voltage Over...

Страница 7: ...changed Flashing Access in I O check mode Yellow Red Flashing Bus error during active I O check Red Flashing Local bus error on startup Solid General local bus error Communication error Local bus devi...

Страница 8: ...ings and 3D models visit ni com dimensions and search for the module number Figure 9 REM 11180 Dimensions 125 9 mm 4 96 in 122 4 mm 4 82 in 74 0 mm 2 97 in 45 0 mm 1 77 in Configuring the Rotary Encod...

Страница 9: ...0 2 Press and hold the reset button 3 Power on the REM 11180 4 Release the button when the RDY LED flashes red and green Reading Error Codes from REM 11180 IOVs When you add the REM 11180 to the RT Ta...

Страница 10: ...a ring memory in Overwrite mode The last 16 diagnostic messages are always stored Older messages are deleted Bus coupler and I O errors are stored in the object s diagnostic messages Table 7 Diagnosi...

Страница 11: ...is enabled 06 F_ACTIVE_BIT Active The configuration is active PDI to the devices is possible output data is disabled substitute value behavior 07 F_READY_BIT Ready The local bus master is ready for o...

Страница 12: ...be completed and then try again 090A Value transmitted in Parameter_Count The number of parameters is inconsistent with the service The Parameter_Count parameter does not agree with the number of subs...

Страница 13: ...call 938 Reserved Variable_ID An internal Variable_ID was used Check the call 939 Variable_ID not enabled The Variable_ID is not enabled Password protection Check the call 093A Incorrect Variable_ID...

Страница 14: ...n frame connected 0010 Param Ready Parameterization of modules completed 0020 Run Process data traffic running 0080 Force Mode Startup tool specifies outputs 0100 Ready Fail Communication abort in Rea...

Страница 15: ...alue with a Variable_ID that contains an unknown code Check the call 0A0D A firmware error occurred Restart the device Contact NI if the problem persists 0A18 Invalid Used_Attributes parameter A reser...

Страница 16: ...present with a chip version in the local bus that is not supported Replace the device 0A74 Device number Device of a manufacturer that is not supported present in the local bus Replace the device 0A75...

Страница 17: ...the device Contact NI if the problem persists 0A90 Device number Device was selected for synchronization however it does not support this Select a device that supports synchronization or change the s...

Страница 18: ...device Contact NI if the problem persists 0B01 A hardware or firmware error occurred Restart the device Contact NI if the problem persists 0B02 A hardware or firmware error occurred 0B03 A hardware o...

Страница 19: ...r Codes Code hex Additional code Meaning Remedy 0BD1 The bus could not be activated due to bus malfunctions Check the bus configuration 0BF1 0BF2 0BF3 0C01 Device number The configured module is not a...

Страница 20: ...instance ID Check the configuration Adapt the configuration frame if the modification was done on purpose 0C13 Device number The process data length does not correspond to the configured value The pr...

Страница 21: ...Check the I O supply 3412 Sensor supply not present I O supply voltage failure 3422 Actuator supply not present 5112 Faulty 24 V supply 24 V supply fail Short circuit or overload at the 24 V supply 24...

Страница 22: ...der 7610 Receive buffer full Rx Buf full Read the receive buffer 7611 Transmit buffer full Tx Buf full Check the handshake 7620 EPROM device error CS ROM Restart the device Replace the device if the e...

Страница 23: ...he service used cannot be applied to this object 0607 Object does not exist 0608 Type conflict 0800 xx30 A reserved bit or reserved code was used during parameterization xx Number of the affected elem...

Страница 24: ...ible bus error Check the bus configuration 0F12 Device cannot be reached timeout Check the device 0F13 Device not accessible because it was removed Check the bus configuration 0F21 Invalid device numb...

Страница 25: ...be overwritten 20 Service cannot be executed at present 21 Due to local control service cannot be executed at present 22 Service cannot be executed in current device state device control 23 Service ca...

Страница 26: ...ication Engineers Visit ni com services for NI Factory Installation Services repairs extended warranty and other services Visit ni com register to register your NI product Product registration facilit...

Страница 27: ...niglobal to access the branch office websites which provide up to date contact information support phone numbers email addresses and current events REM 11180 User Manual National Instruments 27...

Страница 28: ...s EULAs and third party legal notices in the readme file for your NI product Refer to the Export Compliance Information at ni com legal export compliance for the NI global trade compliance policy and...

Отзывы: