Chapter 2
LED Indicators and the RESET Button
Using the RESET Button
Figure 2-3 shows the location of the RESET button on the NI CVS-1459RT.
Figure 2-3.
RESET Button Location
Pressing the RESET button resets the processor in the same manner as cycling power.
You can also use the RESET button to troubleshoot network connectivity:
1.
Hold the RESET button for 5 seconds, and then release it to boot the NI CVS-1459RT into
safe mode.
2.
After booting the controller into safe mode, hold the RESET button again for 5 seconds to
enable IP reset, which resets the network adapter to its default configuration.
The following sections describe safe mode and IP reset.
Speed
Unlit
No link, or 10 Mbps link
Green
100 Mbps link
Amber
1,000 Mbps link