B-5
Figure B-4.
Bottom View of the NI CVS-1459RT with Dimensions
Complete the following steps to secure the NI CVS-1459RT to a mount.
1.
Align the screw holes of the mounting bracket with the two holes on the back of the
NI CVS-1459RT.
2.
Insert two 6-32 screws and tighten them until they are secure (3.5 in-lb). Make sure the
heads of the screws are flush with the mounting bracket.
Clearance Requirements
The NI CVS-1459RT installation must meet the following space and cabling clearance
requirements for optimum cooling:
•
Allow 76.2 mm (3.0 in.) on the top and bottom of the NI CVS-1459RT for air circulation.
•
Allow 50.8 mm (2.0 in.) on the sides of the NI CVS-1459RT for air circulation.
•
Allow enough space in front of the NI CVS-1459RT to connect cables.