Safe Mode
When you boot the NI CVS-1459RT into safe mode, it launches only the services necessary for
updating its configuration and installing software. To resume normal operations, press the
RESET button for less than 5 seconds.
IP Reset
Use IP reset to reset the TCP/IP settings when moving the system from one subnet to another or
when the current TCP/IP settings are invalid.
When the NI CVS-1459RT is in the IP reset state
,
the IP address of the network port resets to
DHCP or a link-local address. You can then set up a new network configuration for the
NI CVS-1459RT from a development machine on the same subnet, or you can connect the
NI CVS-1459RT directly to the development computer.
Note
By default, the target automatically attempts to connect to the network using
DHCP. If the target is unable to initiate a DHCP connection, the target connects to the
network with a link-local IP address (
169.254.x.x
).