35
Gas Furnace
Poor Connection
• Loose or broken connection on the sensor to the board
• Poor ground connection
• With an ohmmeter check for continuity between the spark rod and the wire back to the
board
Grounded Ignitor
• Make sure the ignitor rod is not grounded to the furnace assembly or heat exchanger tube.
Burner Assembly
On Non-Condensing Models the burner is a single orifice ribbon style burner.
Furnace Size (Btuh)
28k
38k
51k
64k
Orifice Size (NG)
#39
#31
#28
#22
Orifice Size (LP)
#53
#49
2.1 mm
#41
On Condensing Models the burner assembly has multiple inshot burners with their own
individual orifices.
Furnace Size (Btuh)
25k
32k
43k
50k
Orifice Size (NG)
#51
#48
#50
#47
Orifice Size (LP)
#58
N/A
#60
#56
Total Burners
2
2
3
3