W415-1013 / B / 07.24.13
9
EN
W3
85
-04
13
E /
07
.14
.10
LIS
TE
D
SO
LID
F
UE
L F
IR
ED
C
EN
TR
AL
F
UR
NA
CE
TESTED
TO:
CAN-CSA
B366-1-M91
/ UL391
4th
Ed
2006
(JUL
Y 2008)
/ UL
727
/ CSA
B140.4
/ CSA
B212
MODEL:
HMF150
REPORT NO.:
_415-S-09-2
CAU
TIO
N:
HO
T W
HI
LE
IN
O
PE
RA
TIO
N.
DO
NO
T T
OU
CH
. K
EE
P C
HI
LD
RE
N,
CL
OT
HI
NG
AN
D
FU
RN
ITU
RE
AW
AY
. C
ON
TA
CT
M
AY
CA
US
E S
KI
N B
UR
NS
. S
EE
NA
ME
PL
AT
E A
ND
IN
ST
RU
CT
IO
NS
.
TECHNIC
AL DA
TA
BL
OWER MO
TOR
1/3 HP
ELECTRIC
AL R
ATING
120V
, 11 AMPS,
60Hz
ELECTRIC FURNA
CE MODULE 220V
, 84 AMPS
EX
TERNAL ST
ATIC PRESSURE 0.2”
W.C.,
0.2”
C.E
.
DR
AFT PRESSURE
WOOD FL
UE:
MIN.
0.04“
W.C.
TO MA
X. 0.06”
W.C.
OIL FL
UE:
MIN.
0.02”
W.C.
TO MA
X. 0.04”
W.C.
OIL FURNA
CE MA
X. FIRING R
ATE 91,000 B
TU INPUT
AS SHIPPED:
- OIL PRESSURE:
120 PSI
- NOZZLE:
0.65 - 60°A
- NO
. 2 FURNA
CE OIL
INS
TA
LL
AT
IO
N U
SE
O
NL
Y I
N A
CC
OR
DA
NC
E W
ITH
W
OL
F S
TE
EL
LT
D’S
IN
ST
RU
CT
IO
NS
. C
ON
TA
CT
LO
CA
L B
UIL
DIN
G
OR
FI
RE
O
FF
ICI
AL
S O
R O
TH
ER
AU
TH
OR
ITI
ES
HA
VIN
G
JU
RIS
DIC
TIO
N A
BO
UT
RE
ST
RIC
TIO
NS
AN
D I
NS
TA
LL
AT
IO
N I
NS
PE
CT
IO
N I
N Y
OU
R A
RE
A.
CAUTION: THIS
APPLIANCE MUST BE INST
ALLED BY
A QUALIFIED INST
ALLER.
USE OF UNAUTHORIZED COMPONENTS OR F
AILURE
TO COMPL
Y WITH INST
ALLA-
TION INSTRUCTIONS WILL
RESUL
T IN VOIDED W
ARRANTY
.
CHIMNEY
TYPE
: FOR “WOOD ONL
Y” FURNACE CONFIGURA
TION MINIMUM 6” (152mm) DIAMETER LISTED (UL
103HT) RESIDENTIAL
CHIMNEY
. FOR “WOOD/OIL
COMBINA
TION” FURNACE RECOMMENDED MINIMUM 7”(178mm) DIAMETER LISTED (UL
103HT) RESIDENTIAL
CHIMNEY
.
CHIMNEY
CONNECT
OR
: 6” (152mm) DIAMETER MINIMUM 24 GAUGE STEEL
MINIMUM CLEARANCE FROM HORIZONT
AL
CONNECT
OR
AND CEILING 18” (455mm).
SPECIAL
METHODS
ARE REQUIRED W
HE
N P
AS
SIN
G A
CH
IM
NE
Y T
HR
OU
GH
A
WA
LL
O
R C
EIL
ING
. S
EE
IN
ST
RU
CT
IO
NS
AN
D B
UIL
DIN
G
CO
DE
S.
DO
N
OT
C
ON
NE
CT
TH
IS
UN
IT
TO
A
CH
IM
NE
Y F
LU
E S
ER
VIN
G
AN
OT
HE
R A
PP
LIA
NC
E.
EX
CE
PT
IO
N
“A
DD
O
N”
C
ON
FIG
UR
AT
IO
N
WI
TH
AN
O
IL
FU
RN
AC
E R
EF
ER
TO
M
AN
UA
L.
DO
N
OT
C
ON
NE
CT
TH
IS
FU
RN
AC
E T
O
A C
HI
MN
EY
SE
RV
IC
E A
G
AS
AP
PL
IA
NC
E.
FUEL
: F
OR
US
E W
ITH
SO
LID
W
OO
D F
UE
L O
NL
Y. D
O N
OT
US
E G
RA
TE
O
R
EL
EV
AT
E F
IR
E.
BU
ILD
W
OO
D
FIR
E D
IR
EC
TL
Y O
N
HE
AR
TH
. LOAD FUEL
CAREFULL
Y OR DAMAGE MA
Y
RESUL
T.
OI
L F
UR
NA
CE
M
OD
UL
E N
O.
2 F
UR
NA
CE
O
IL
DANGER: RISK OF FIRE OR EXPLOSION.
DO NOT
ATTEMPT T
O LIGHT
A FIRE IF THERE IS
AN OIL
VAPOUR PRESENT
.
DO NOT
USE CHEMICALS OR FLUIDS
TO ST
AR
T THE FIRE.
DO
N
OT
BU
RN
G
AR
BA
GE
, G
AS
OL
IN
E,
NA
PH
TA
, E
NG
IN
E O
IL
OR
O
TH
ER
IN
AP
PR
OP
RI
AT
E M
AT
ER
IAL
S.
DO NOT
ST
ORE FUEL
OR COMBUSTIBLE MA
TERIAL
WITHIN INST
ALLA
TION CLEARANCES OF
THE
APPLIANCE.
DO
N
OT
U
SE
TH
IS
FU
RN
AC
E W
ITH
OU
T D
UC
TS
–
SE
E M
AN
UA
L F
OR
AL
LO
WA
BL
E C
ON
FIG
UR
AT
IO
N.
WARNING
:
RISK OF SMOKE SPILLAGE. OPERA
TE ONL
Y WITH FIRING
AND
ASHPIT
DOOR
TIGHTL
Y CLOSED. DO NOT
OVERFIRE.
IF HEA
TER OR CHIMNEY
CONNECT
ORS GLOW
, YOU
ARE OVERFIRING – IMMEDIA
TEL
Y TURN OFF THERMOST
AT
AND
ENSURE PRIMAR
Y SHUTTER FIRING
AND
ASHPIT DOOR
ARE CLOSED.
CA
UT
IO
N
: M
AIN
TA
IN
C
OM
BU
ST
IO
N A
IR
SU
PP
LY
TO
BO
TH
FU
RN
AC
ES
. A
IR
ST
AR
VA
TIO
N
IS
DA
NG
ER
OU
S (
SE
E M
AN
UA
L U
ND
ER
“O
UT
SID
E C
OM
BU
ST
IO
N A
IR
”.
THE HMF150 FURNACE MA
Y BE CONNECTED
TO DUCTWORK (SUPPL
Y SIDE – SEE MANUAL) OF
ANOTHER FURNACE WHEN USED
AS
AN WOOD FURNACE “ADD-ON”.
CE
RT
IFI
ED
FO
R
SE
RI
ES
C
ON
NE
CT
IO
N
TO
TH
E S
UP
PL
Y P
LE
NU
M
OU
TL
ET
O
NL
Y O
F A
G
AS
FI
RE
D,
O
IL
FIR
ED
, O
R
EL
EC
TR
IC
FU
RN
AC
E.
DO NOT CONNECT DUCTWORK SO THA
T REVERSE FLOW IS POSSIBLE.
FO
R
“A
DD
O
N”
IN
ST
AL
LA
TIO
N
RE
FE
R
TO
M
AN
UF
AC
TU
RE
S I
NS
TR
UC
TIO
NS
FR
OM
O
RI
GI
NA
L F
UR
NA
CE
FO
R
IN
FO
RM
AIT
ON
O
N
MI
NI
MU
M
DU
CT
SI
ZIN
G,
AL
LO
WA
BL
E
DU
CT
O
PE
NI
NG
S I
N
FU
RN
AC
E C
AS
IN
G
AN
D
EL
EC
TR
IC
D
IAG
RA
MS
AN
D
IN
FO
RM
AT
IO
N.
DO NOT RELOCA
TE OR BYP
ASS
ANY
OF THE SAFETY
CONTROLS IN THE ORIGINAL
FURNACE INST
ALLA
TION (“ADD ON” CONFIGURA
TION).
DO NOT OBSTRUCT SP
ACE UNDER FURNACE.
UNIT
CAN BE INST
ALLED ON COMBUSTIBLE SURF
ACE (WOOD SUBSTRA
TE ONL
Y – CARPET
AND OTHER FLOOR
COVERINGS
TO BE REMOVED) PROVIDING EMBER ST
OP
SHIELD (SEE MANUAL) INST
ALLED BETWEEN FURNACE
AND FLOOR
AND MINIMUM 1
1/4”
AIR GAP
MAINT
AINED BETWEEN FURNACE
AND FLOOR.
INCASE OF POWER F
AILURE: PUSH DOWN ON
THE CONTROL
ARM OF
THE PRIMAR
Y AIR CONTROL
AND LOCK IT
DOWN USING ROT
ATING CLASP
. T
O
AVOID
EXCESSIVE HEA
T BEING
TRAPPED IN DUCT
WORK ENSURE
ALL
RETURN
AND SUPPL
Y AIR REGISTERS
ARE NOT
BLOCKED BY
OBJECTS OR DEBRIS
AND
ALL
DUCT
CONTROL
DAMPERS
ARE SET
OPEN. S
EE
M
AN
UA
L F
OR
O
PE
RA
TIO
N O
F W
OO
D F
UR
NA
CE
IF
EL
EC
TR
ICA
L P
OW
ER
HA
S B
EE
N I
NT
ER
RU
PT
ED
.
OP
ER
AT
E O
RI
GI
NA
L F
UR
NA
CE
(E
LE
CT
RI
C,
O
IL,
G
AS
) O
F A
“A
DD
O
N”
C
ON
FIG
UR
AT
IO
N
PE
RI
OD
IC
AL
LY
TO
EN
SU
RE
IT
W
ILL
O
PE
RA
TE
SA
TIS
FA
CT
OR
ILY
W
HE
N
NE
ED
ED
.
THE HEA
T EXCHANGER, FLUE PIPE
AND CHIMNEY
MUST
BE INSPECTED FREQUENTL
Y AND CLEANED REGULARL
Y T
O REMOVE
ACCUMULA
TED CREOSOTE
AND
ASH. UNDER CER
TAIN CONDITIONS OF USE, CREOSOTE BUILDUP
MA
Y OCCUR RAPIDL
Y. ENSURE
THA
T THE HEA
T EXCHANGER, FLUE PIPE
AND CHIMNEY
ARE
CLEANED
AT
END OF BURNING SEASON,
THIS HELPS
TO MINIMIZE CORROSION IN
THE SUMMER MONTHS.
THE
APPLIANCE, FLUE PIPE
AND CHIMNEY
MUST
BE
MAINT
AINED IN GOOD CONDITION. UNSAFE
TO FIRE WITH WOOD
ABOVE
TOP
OF REFRACT
OR
Y BRICK INSIDE COMBUSTIBLE CHAMBER.
US
E S
UP
PL
Y W
IRE
S S
UIT
AB
LE
FO
R 1
67
°F/
75
°C
. S
EE
IN
ST
RU
CT
IO
N M
AN
UA
L F
OR
EL
EC
TR
ICA
L D
IAG
RA
M.
DANGER
: RISK OF ELECTRICAL
SHOCK. DISCONNECT
POWER BEFORE SER
VICING UNIT
. F
OR
M
OR
E I
NF
OR
MA
TIO
N
RE
FE
R
TO
O
WN
ER
’S
MA
NU
AL
.
CA
UT
IO
N
: T
WO
SO
UR
CE
S O
F E
LE
CT
RI
CA
L E
NE
RG
Y P
RE
SE
NT
IN
EL
EC
TR
IC
FU
RN
AC
E M
OD
UL
E -
D
ISC
ON
NE
CT
22
0V
SU
PP
LY
TO
M
OD
UL
E A
ND
12
0V
SU
PP
LY
TO
HM
F1
50
FU
RN
AC
E B
EF
OR
E S
ER
VIC
IN
G.
REPLACE
ALL
CRACKED OR BROKEN FIRE BRICK
AND
TOP
BAFFLES. REPLACE GLASS ONL
Y WITH CERAMIC GLASS.
AU
TH
OR
IZE
D M
OD
UL
ES
FO
R C
ON
NE
CT
IO
N T
O
HM
F1
50
FU
RN
AC
E
: BLOWER BOX MODULE -
HMFK-BMP33
, ELECTRIC FURNACE MODULE-
HMFK-EF20,
OIL
FURNACE
MODULES -
HMFK-OFRF40
,
HMFK-OF
AFG,
DHW PREHEA
T MODULE -
HMFK-DHW
,
“ADD ON” KIT
-
HMFK-ADDON
THESE
ARE
THE ONL
Y AUTHORIZED COMPONENTS
THA
T MA
Y BE
ATT
ACHED
TO
THE HMF150 FURNACE
ASIDE FROM CONNECTION
TO FORCED
AIR SYSTEM
RETURN
AND SUPPL
Y PLENUMS. MODULES MUST
BE INST
ALLED
TO MANUF
ACTURERS INSTRUCTIONS POSTED IN
THE INST
ALLA
TION/OWNERS MANUAL
ACCOMP
A-
NYING HMF150
AND INSTRUCTION
ADDENDUMS INCLUDED WITH EACH MODULE.
HMF150 CONFIGURED
AS
AN “ADD ON”:
MA
Y B
E A
DD
ED
O
NT
O
A F
UR
NA
CE
H
AV
IN
G
A R
AT
IN
G
AS
SH
OW
N
ON
TH
E O
RI
GI
NA
L N
AM
E P
LA
TE
BE
TW
EE
N:
.:
0,1
,08
0$
1'
.:
0$
;,0
80
)2
5(
/(&
75,
&)
85
1$&
(
0
,1,0
80
$1
'
0$
;,0
80
86
*3
+)
25
2,/
)8
51
$&(
,13
87
0$
;,0
80
%7
8+
)2
5*
$6
)85
1$&
(,1
387
RE
FE
R
TO
O
WN
ER
S M
AN
UA
L
WO
LF
ST
EE
L
LT
D.
24
N
AP
OL
EO
N
RO
AD
, B
AR
RI
E,
ON
, L
4M
4Y
8 C
AN
AD
A
18”
MA
X 16”
CLEAR
ANCE
TO C
OMBUSIBLES
SER
VICE CLEAR
ANCE
24”
14”
CLEAR
ANCE
TO C
OMBUSIBLES
SER
VICE CLEAR
ANCE
24”
LEFT HAND R
A C
ONFIGUR
ATION (REAR
VIE
W)
MINIMUM 40”
18”
14”
MINIMUM 52”
9”
*Dra
wing not t
o scale
OIL FURNA
CE FL
UE
WOOD
, W
OOD/OIL FL
UE
NO
TE
5
()(
57
20
$18
$/)
25
5,*
+7
+$1
'&
21
),*
85
$7,
21
&/
($5
$1&
(7
2&
20
%86
7,%
/(6
7
+(
(/(
&75
,&)
85
1$&
(0
2'
8/(
12
76
+2
:1
)$
//6
:,
7+,
1(
19(
/23
(2
)&
/($
5$1
&(
72
&2
0%
867
,%/
(6
)25
:2
2'
:
22
'2
,/&
21
),*
85
$7,
21
7+
(&
/($
5$1
&(
(19
(/2
3(6
'2
12
7
CH
AN
GE
W
ITH
AD
DIT
IO
N O
F T
HE
EL
EC
TR
IC
FU
RN
AC
E.
CLEAR
ANCE
TO C
OMBUSTIBLES
CLEAR
ANCE
TO C
OMBUSTIBLES
48”
18”
24”
1.25”
CLEAR
ANCE
TO C
OMBUSTIBLES
SER
VICE CLEAR
ANCE
LEFT HAND R
A C
ONFIGUR
ATION (SIDE
VIE
W BL
OWER MODULE)
9”
*Dra
wing not t
o scale
OIL FURNA
CE FL
UE
WOOD
, W
OOD/OIL FL
UE
NO
TE:
SEC
TION
“C” CLEAR
ANCES M
AY BE REDUCED
TO 0.375”
BE
YOND A BEND OR
OFFSE
T IN
THE DUC
T SUFFICIENTL
Y LAR
GE
TO SHIELD
THE REM
AINDER OF
THE SUPPL
Y DUC
T FR
OM DIREC
T R
ADIA
TION FR
OM
THE FURNA
CE HEA
T
EXCHANGER.
72”
1”
6”
7 f
t. MINIMUM CEILING HEIGHT
CLEAR
ANCE
TO C
OMBUSTIBLES
40”
>72”
A
B
C
NO
TE:
See
CAN/CSA-
B365.01 and
NFP
A211 f
or
clear
anc
e to
combustible
specifica
tions
for r
etur
n air
duc
ting
.
*Dra
wing not t
o scale
CLEARANCE
TO
COMBUSTIBLES
SECTION
A
B
C
TOP
6”
6”
1”
BOTT
OM/SIDES
18”
6”
1”
SERIAL
NO.
HM
F1
50
MANUF
ACTURE DA
TE:
JAN
APR
JUL
OCT
FEB
MA
Y
AUG
NOV
MAR
JUN
SEP
DEC
2010
2011
2012
2013
W3
85
-04
13
E /
07
.14
.10
LIS
TE
D
SO
LID
F
UE
L F
IR
ED
C
EN
TR
AL
F
UR
NA
CE
TESTED
TO:
CAN-CSA
B366-1-M91
/ UL391
4th
Ed
2006
(JUL
Y 2008)
/ UL
727
/ CSA
B140.4
/ CSA
B212
MODEL:
HMF150
REPORT NO.:
_415-S-09-2
CAU
TIO
N:
HO
T W
HI
LE
IN
O
PE
RA
TIO
N.
DO
NO
T T
OU
CH
. K
EE
P C
HI
LD
RE
N,
CL
OT
HI
NG
AN
D
FU
RN
ITU
RE
AW
AY
. C
ON
TA
CT
M
AY
CA
US
E S
KI
N B
UR
NS
. S
EE
NA
ME
PL
AT
E A
ND
IN
ST
RU
CT
IO
NS
.
TECHNIC
AL DA
TA
BL
OWER MO
TOR
1/3 HP
ELECTRIC
AL R
ATING
120V
, 11 AMPS,
60Hz
ELECTRIC FURNA
CE MODULE 220V
, 84 AMPS
EX
TERNAL ST
ATIC PRESSURE 0.2”
W.C.,
0.2”
C.E
.
DR
AFT PRESSURE
WOOD FL
UE:
MIN.
0.04“
W.C.
TO MA
X. 0.06”
W.C.
OIL FL
UE:
MIN.
0.02”
W.C.
TO MA
X. 0.04”
W.C.
OIL FURNA
CE MA
X. FIRING R
ATE 91,000 B
TU INPUT
AS SHIPPED:
- OIL PRESSURE:
120 PSI
- NOZZLE:
0.65 - 60°A
- NO
. 2 FURNA
CE OIL
INS
TA
LL
AT
IO
N U
SE
O
NL
Y I
N A
CC
OR
DA
NC
E W
ITH
W
OL
F S
TE
EL
LT
D’S
IN
ST
RU
CT
IO
NS
. C
ON
TA
CT
LO
CA
L B
UIL
DIN
G
OR
FI
RE
O
FF
ICI
AL
S O
R O
TH
ER
AU
TH
OR
ITI
ES
HA
VIN
G
JU
RIS
DIC
TIO
N A
BO
UT
RE
ST
RIC
TIO
NS
AN
D I
NS
TA
LL
AT
IO
N I
NS
PE
CT
IO
N I
N Y
OU
R A
RE
A.
CAUTION: THIS
APPLIANCE MUST BE INST
ALLED BY
A QUALIFIED INST
ALLER.
USE OF UNAUTHORIZED COMPONENTS OR F
AILURE
TO COMPL
Y WITH INST
ALLA-
TION INSTRUCTIONS WILL
RESUL
T IN VOIDED W
ARRANTY
.
CHIMNEY
TYPE
: FOR “WOOD ONL
Y” FURNACE CONFIGURA
TION MINIMUM 6” (152mm) DIAMETER LISTED (UL
103HT) RESIDENTIAL
CHIMNEY
. FOR “WOOD/OIL
COMBINA
TION” FURNACE RECOMMENDED MINIMUM 7”(178mm) DIAMETER LISTED (UL
103HT) RESIDENTIAL
CHIMNEY
.
CHIMNEY
CONNECT
OR
: 6” (152mm) DIAMETER MINIMUM 24 GAUGE STEEL
MINIMUM CLEARANCE FROM HORIZONT
AL
CONNECT
OR
AND CEILING 18” (455mm).
SPECIAL
METHODS
ARE REQUIRED W
HE
N P
AS
SIN
G A
CH
IM
NE
Y T
HR
OU
GH
A
WA
LL
O
R C
EIL
ING
. S
EE
IN
ST
RU
CT
IO
NS
AN
D B
UIL
DIN
G
CO
DE
S.
DO
N
OT
C
ON
NE
CT
TH
IS
UN
IT
TO
A
CH
IM
NE
Y F
LU
E S
ER
VIN
G
AN
OT
HE
R A
PP
LIA
NC
E.
EX
CE
PT
IO
N
“A
DD
O
N”
C
ON
FIG
UR
AT
IO
N
WI
TH
AN
O
IL
FU
RN
AC
E R
EF
ER
TO
M
AN
UA
L.
DO
N
OT
C
ON
NE
CT
TH
IS
FU
RN
AC
E T
O
A C
HI
MN
EY
SE
RV
IC
E A
G
AS
AP
PL
IA
NC
E.
FUEL
: F
OR
US
E W
ITH
SO
LID
W
OO
D F
UE
L O
NL
Y. D
O N
OT
US
E G
RA
TE
O
R
EL
EV
AT
E F
IR
E.
BU
ILD
W
OO
D
FIR
E D
IR
EC
TL
Y O
N
HE
AR
TH
. LOAD FUEL
CAREFULL
Y OR DAMAGE MA
Y
RESUL
T.
OI
L F
UR
NA
CE
M
OD
UL
E N
O.
2 F
UR
NA
CE
O
IL
DANGER: RISK OF FIRE OR EXPLOSION.
DO NOT
ATTEMPT T
O LIGHT
A FIRE IF THERE IS
AN OIL
VAPOUR PRESENT
.
DO NOT
USE CHEMICALS OR FLUIDS
TO ST
AR
T THE FIRE.
DO
N
OT
BU
RN
G
AR
BA
GE
, G
AS
OL
IN
E,
NA
PH
TA
, E
NG
IN
E O
IL
OR
O
TH
ER
IN
AP
PR
OP
RI
AT
E M
AT
ER
IAL
S.
DO NOT
ST
ORE FUEL
OR COMBUSTIBLE MA
TERIAL
WITHIN INST
ALLA
TION CLEARANCES OF
THE
APPLIANCE.
DO
N
OT
U
SE
TH
IS
FU
RN
AC
E W
ITH
OU
T D
UC
TS
–
SE
E M
AN
UA
L F
OR
AL
LO
WA
BL
E C
ON
FIG
UR
AT
IO
N.
WARNING
:
RISK OF SMOKE SPILLAGE. OPERA
TE ONL
Y WITH FIRING
AND
ASHPIT
DOOR
TIGHTL
Y CLOSED. DO NOT
OVERFIRE.
IF HEA
TER OR CHIMNEY
CONNECT
ORS GLOW
, YOU
ARE OVERFIRING – IMMEDIA
TEL
Y TURN OFF THERMOST
AT
AND
ENSURE PRIMAR
Y SHUTTER FIRING
AND
ASHPIT DOOR
ARE CLOSED.
CA
UT
IO
N
: M
AIN
TA
IN
C
OM
BU
ST
IO
N A
IR
SU
PP
LY
TO
BO
TH
FU
RN
AC
ES
. A
IR
ST
AR
VA
TIO
N
IS
DA
NG
ER
OU
S (
SE
E M
AN
UA
L U
ND
ER
“O
UT
SID
E C
OM
BU
ST
IO
N A
IR
”.
THE HMF150 FURNACE MA
Y BE CONNECTED
TO DUCTWORK (SUPPL
Y SIDE – SEE MANUAL) OF
ANOTHER FURNACE WHEN USED
AS
AN WOOD FURNACE “ADD-ON”.
CE
RT
IFI
ED
FO
R
SE
RI
ES
C
ON
NE
CT
IO
N
TO
TH
E S
UP
PL
Y P
LE
NU
M
OU
TL
ET
O
NL
Y O
F A
G
AS
FI
RE
D,
O
IL
FIR
ED
, O
R
EL
EC
TR
IC
FU
RN
AC
E.
DO NOT CONNECT DUCTWORK SO THA
T REVERSE FLOW IS POSSIBLE.
FO
R
“A
DD
O
N”
IN
ST
AL
LA
TIO
N
RE
FE
R
TO
M
AN
UF
AC
TU
RE
S I
NS
TR
UC
TIO
NS
FR
OM
O
RI
GI
NA
L F
UR
NA
CE
FO
R
IN
FO
RM
AIT
ON
O
N
MI
NI
MU
M
DU
CT
SI
ZIN
G,
AL
LO
WA
BL
E
DU
CT
O
PE
NI
NG
S I
N
FU
RN
AC
E C
AS
IN
G
AN
D
EL
EC
TR
IC
D
IAG
RA
MS
AN
D
IN
FO
RM
AT
IO
N.
DO NOT RELOCA
TE OR BYP
ASS
ANY
OF THE SAFETY
CONTROLS IN THE ORIGINAL
FURNACE INST
ALLA
TION (“ADD ON” CONFIGURA
TION).
DO NOT OBSTRUCT SP
ACE UNDER FURNACE.
UNIT
CAN BE INST
ALLED ON COMBUSTIBLE SURF
ACE (WOOD SUBSTRA
TE ONL
Y – CARPET
AND OTHER FLOOR
COVERINGS
TO BE REMOVED) PROVIDING EMBER ST
OP
SHIELD (SEE MANUAL) INST
ALLED BETWEEN FURNACE
AND FLOOR
AND MINIMUM 1
1/4”
AIR GAP
MAINT
AINED BETWEEN FURNACE
AND FLOOR.
INCASE OF POWER F
AILURE: PUSH DOWN ON
THE CONTROL
ARM OF
THE PRIMAR
Y AIR CONTROL
AND LOCK IT
DOWN USING ROT
ATING CLASP
. T
O
AVOID
EXCESSIVE HEA
T BEING
TRAPPED IN DUCT
WORK ENSURE
ALL
RETURN
AND SUPPL
Y AIR REGISTERS
ARE NOT
BLOCKED BY
OBJECTS OR DEBRIS
AND
ALL
DUCT
CONTROL
DAMPERS
ARE SET
OPEN. S
EE
M
AN
UA
L F
OR
O
PE
RA
TIO
N O
F W
OO
D F
UR
NA
CE
IF
EL
EC
TR
ICA
L P
OW
ER
HA
S B
EE
N I
NT
ER
RU
PT
ED
.
OP
ER
AT
E O
RI
GI
NA
L F
UR
NA
CE
(E
LE
CT
RI
C,
O
IL,
G
AS
) O
F A
“A
DD
O
N”
C
ON
FIG
UR
AT
IO
N
PE
RI
OD
IC
AL
LY
TO
EN
SU
RE
IT
W
ILL
O
PE
RA
TE
SA
TIS
FA
CT
OR
ILY
W
HE
N
NE
ED
ED
.
THE HEA
T EXCHANGER, FLUE PIPE
AND CHIMNEY
MUST
BE INSPECTED FREQUENTL
Y AND CLEANED REGULARL
Y T
O REMOVE
ACCUMULA
TED CREOSOTE
AND
ASH. UNDER CER
TAIN CONDITIONS OF USE, CREOSOTE BUILDUP
MA
Y OCCUR RAPIDL
Y. ENSURE
THA
T THE HEA
T EXCHANGER, FLUE PIPE
AND CHIMNEY
ARE
CLEANED
AT
END OF BURNING SEASON,
THIS HELPS
TO MINIMIZE CORROSION IN
THE SUMMER MONTHS.
THE
APPLIANCE, FLUE PIPE
AND CHIMNEY
MUST
BE
MAINT
AINED IN GOOD CONDITION. UNSAFE
TO FIRE WITH WOOD
ABOVE
TOP
OF REFRACT
OR
Y BRICK INSIDE COMBUSTIBLE CHAMBER.
US
E S
UP
PL
Y W
IRE
S S
UIT
AB
LE
FO
R 1
67
°F/
75
°C
. S
EE
IN
ST
RU
CT
IO
N M
AN
UA
L F
OR
EL
EC
TR
ICA
L D
IAG
RA
M.
DANGER
: RISK OF ELECTRICAL
SHOCK. DISCONNECT
POWER BEFORE SER
VICING UNIT
. F
OR
M
OR
E I
NF
OR
MA
TIO
N
RE
FE
R
TO
O
WN
ER
’S
MA
NU
AL
.
CA
UT
IO
N
: T
WO
SO
UR
CE
S O
F E
LE
CT
RI
CA
L E
NE
RG
Y P
RE
SE
NT
IN
EL
EC
TR
IC
FU
RN
AC
E M
OD
UL
E -
D
ISC
ON
NE
CT
22
0V
SU
PP
LY
TO
M
OD
UL
E A
ND
12
0V
SU
PP
LY
TO
HM
F1
50
FU
RN
AC
E B
EF
OR
E S
ER
VIC
IN
G.
REPLACE
ALL
CRACKED OR BROKEN FIRE BRICK
AND
TOP
BAFFLES. REPLACE GLASS ONL
Y WITH CERAMIC GLASS.
AU
TH
OR
IZE
D M
OD
UL
ES
FO
R C
ON
NE
CT
IO
N T
O
HM
F1
50
FU
RN
AC
E
: BLOWER BOX MODULE -
HMFK-BMP33
, ELECTRIC FURNACE MODULE-
HMFK-EF20,
OIL
FURNACE
MODULES -
HMFK-OFRF40
,
HMFK-OF
AFG,
DHW PREHEA
T MODULE -
HMFK-DHW
,
“ADD ON” KIT
-
HMFK-ADDON
THESE
ARE
THE ONL
Y AUTHORIZED COMPONENTS
THA
T MA
Y BE
ATT
ACHED
TO
THE HMF150 FURNACE
ASIDE FROM CONNECTION
TO FORCED
AIR SYSTEM
RETURN
AND SUPPL
Y PLENUMS. MODULES MUST
BE INST
ALLED
TO MANUF
ACTURERS INSTRUCTIONS POSTED IN
THE INST
ALLA
TION/OWNERS MANUAL
ACCOMP
A-
NYING HMF150
AND INSTRUCTION
ADDENDUMS INCLUDED WITH EACH MODULE.
HMF150 CONFIGURED
AS
AN “ADD ON”:
MA
Y B
E A
DD
ED
O
NT
O
A F
UR
NA
CE
H
AV
IN
G
A R
AT
IN
G
AS
SH
OW
N
ON
TH
E O
RI
GI
NA
L N
AM
E P
LA
TE
BE
TW
EE
N:
.:
0,1
,08
0$
1'
.:
0$
;,0
80
)2
5(
/(&
75,
&)
85
1$&
(
0
,1,0
80
$1
'
0$
;,0
80
86
*3
+)
25
2,/
)8
51
$&(
,13
87
0$
;,0
80
%7
8+
)2
5*
$6
)85
1$&
(,1
387
RE
FE
R
TO
O
WN
ER
S M
AN
UA
L
WO
LF
ST
EE
L
LT
D.
24
N
AP
OL
EO
N
RO
AD
, B
AR
RI
E,
ON
, L
4M
4Y
8 C
AN
AD
A
18”
MA
X 16”
CLEAR
ANCE
TO C
OMBUSIBLES
SER
VICE CLEAR
ANCE
24”
14”
CLEAR
ANCE
TO C
OMBUSIBLES
SER
VICE CLEAR
ANCE
24”
LEFT HAND R
A C
ONFIGUR
ATION (REAR
VIE
W)
MINIMUM 40”
18”
14”
MINIMUM 52”
9”
*Dra
wing not t
o scale
OIL FURNA
CE FL
UE
WOOD
, W
OOD/OIL FL
UE
NO
TE
5
()(
57
20
$18
$/)
25
5,*
+7
+$1
'&
21
),*
85
$7,
21
&/
($5
$1&
(7
2&
20
%86
7,%
/(6
7
+(
(/(
&75
,&)
85
1$&
(0
2'
8/(
12
76
+2
:1
)$
//6
:,
7+,
1(
19(
/23
(2
)&
/($
5$1
&(
72
&2
0%
867
,%/
(6
)25
:2
2'
:
22
'2
,/&
21
),*
85
$7,
21
7+
(&
/($
5$1
&(
(19
(/2
3(6
'2
12
7
CH
AN
GE
W
ITH
AD
DIT
IO
N O
F T
HE
EL
EC
TR
IC
FU
RN
AC
E.
CLEAR
ANCE
TO C
OMBUSTIBLES
CLEAR
ANCE
TO C
OMBUSTIBLES
48”
18”
24”
1.25”
CLEAR
ANCE
TO C
OMBUSTIBLES
SER
VICE CLEAR
ANCE
LEFT HAND R
A C
ONFIGUR
ATION (SIDE
VIE
W BL
OWER MODULE)
9”
*Dra
wing not t
o scale
OIL FURNA
CE FL
UE
WOOD
, W
OOD/OIL FL
UE
NO
TE:
SEC
TION
“C” CLEAR
ANCES M
AY BE REDUCED
TO 0.375”
BE
YOND A BEND OR
OFFSE
T IN
THE DUC
T SUFFICIENTL
Y LAR
GE
TO SHIELD
THE REM
AINDER OF
THE SUPPL
Y DUC
T FR
OM DIREC
T R
ADIA
TION FR
OM
THE FURNA
CE HEA
T
EXCHANGER.
72”
1”
6”
7 f
t. MINIMUM CEILING HEIGHT
CLEAR
ANCE
TO C
OMBUSTIBLES
40”
>72”
A
B
C
NO
TE:
See
CAN/CSA-
B365.01 and
NFP
A211 f
or
clear
anc
e to
combustible
specifica
tions
for r
etur
n air
duc
ting
.
*Dra
wing not t
o scale
CLEARANCE
TO
COMBUSTIBLES
SECTION
A
B
C
TOP
6”
6”
1”
BOTT
OM/SIDES
18”
6”
1”
SERIAL
NO.
HM
F1
50
MANUF
ACTURE DA
TE:
JAN
APR
JUL
OCT
FEB
MA
Y
AUG
NOV
MAR
JUN
SEP
DEC
2010
2011
2012
2013
0
2
4
6
8
10
5 10 15 20 25
AIR INTAKE LINERS
HORIZONTAL RUN
VER
TICAL
RISE
H12.2.1
The vertical height of the air intake liner must not be greater than 2/3 the
height of the chimney.
The duct terminations must be located so they can not be blocked (i.e.
snowdrifts). 4' (1.22m) above grade or above maximum snow grade for the
area is recommended. make a 4 1/2" inch (114 mm) hole to suit in an out-
side wall of the house. from outside, place the fresh air hood into the hole,
open side down. Seal with caulking and secure.
The 4" (102mm) inlet can also draw combustion air from the room provided adequate make up air is available.
fresh air makeup for the oil furnaces must follow criteria set in installation standard CSa b139-09 "installation
Code For Oil Burning Equipment", and installed by a certified oil mechanic.
Fresh air makeup for gas fired furnaces must follow criteria set in installation standard CAN/CGA-B149.1 or
Can/CGa-b149.2.
fresh air makeup solid fuel furnaces must follow criteria set in installation standard Can/CSa-b365.
veRtIcal RIse BetWeen
hoRIZoNTAL RUN
6’ & 10’ (1.83m & 3.05m) max
5’ (1.52m)
3’ & 6’ (0.91m & 1.83m)
15’ (4.57m)
1’ & 3’ (0.31m & 0.91m)
20’ (6.10m)
0’ & 1’ (0m & 0.31m)
25’ (7.62m)
h12.10.1
h3.35
WhEN INSTALLINg A SySTEM FoR MAkE Up FRESh AIR, ThE INSTALLER MUST TAkE INTo
ACCoUNT A SATISFACToRy AIR MAkE Up RATE IN ThE LIkELIhood ThAT MoRE ThAN oNE
Fuel-BuRnIng FuRnace In a MultI FuRnace cOnFIguRatIOn MaY OpeRate at tHe saMe
TIME.