W415-1013 / B / 07.24.13
23
EN
required ComPonenTS:
• Hmf150/200 Hybrid furnace
• Hmfk-bmP50-1 blower box module
• Hmfk-Solid or Hmfk-GlaSS door kit
STEpS:
Completely assemble HMF150/200 in required left or right hand "RA" configuration as required.
STEp #1 - #4
Follow Steps 1 to 4 from SECTION 5.1 - HYBRID
HMF150/200 AS A "ADD ON" TO EXISTING FURNACE.
STEp #5
○
locate and level the Hmf150/200 while maintain-
ing a minimum 1.25" (32mm) clearance space
between the bottom of the furnace and floor.
○
use levelling the legs to compensate for uneven
floor and snug lock nuts up to the furnace base to
prevent movement through vibration.
○
remove the contents of the blower module kit
and compare with the contents list on the "manu-
al" addendum, accompanying the blower module.
STEp #6
○
Place the blower box module with the blower
outlet side facing the rectangular opening on the
side panel.
○ Adjust the levelling legs on the blower box mod
-
ule so that the module is level and clearance hole
on the mounting flanges align with pilot holes on
side of the furnace panel.
step #7
○
lift the blower outlet side of blower box so mount-
ing flange on the bottom of blower box clears the
retaining bracket on the lower edge of the furnace
side.
○
Slide the blower box in so the lower mounting
flange of the blower box is contained between the
flange of the retaining bracket and the furnace
side.
○ Fasten the sides and top mounting flanges of the
blower box using wildrill 1/4" hex head screws.
2
1
3
4
LEvEL LEg
LoCk NUT
RETAINING FLANGE
5.2 HyBrId HmF150/200 AS A “STANd ALONE” wOOd FurNACE
ITEM
DESCRIPTION
QTY
1 HMF150/200 HYBRID FURNACE
1
2 HMFK-BMP50 BLOWER BOX MODULE
1
3 1/4" HEX HEAD WILDRIL SCREW
11
4 HMFK - SOLID or HMFK - GLASS DOOR KIT 1
h3.41
tHe InstallatIOn OF tHe WOOD FuRnace / cOMBInatIOn WOOD FuRnace Must Be DOne In
accORDance WItH Rules OF autHORItIes HavIng JuRIsDIctIOn anD tHe can / csa B365-01
(R2006) stanDaRD FOR sOlID Fuel BuRnIng applIances anD eQuIpMent.