The napoleon Hmf150/200 may take outside combustion air directly into the appliance through a 4" (102mm)
inlet collar at the back of the unit. This inlet is to supply combustion air for the Hmf150/200 wood furnace
only.
Secure and seal the intake liners to the collars using 3 sheet metal screws, and high temperature sealant.
insulating the intake liners is recommended in colder climates to prevent condensation from occurring.
for detailed clearance to combustibles, see Section 6.0 for plenum and consideration of venting location.
3.0 INSTALLATION PLANNING
3.1 LOCATION ANd CLEArANCES
3.2 OuTSIdE COmBuSTION AIr
h3.32
WEAR gLovES ANd SAFETy gLASSES FoR pRoTECTIoN.
kEEp hANd TooLS IN good CoNdITIoN, ShARpEN CUTTINg EdgES ANd MAkE SURE TooL
hANdLES ARE SECURE.
DO nOt MakesHIFt cOMpROMIses DuRIng InstallatIOn. DO nOt BlOck OR RestRIct aIR.
DO nOt IMpeDe aIR MOveMent zOnes MaRkeD “cleaRance tO cOMBustIBles”.
h3.33
FoR hMF150 do NoT INSTALL INTo ANy AREA hAvINg A hEIghT LESS ThAN 6 FEET 3 INChES (1.9M)
(can Be ReDuceD tO 6 Feet (1.8M) WHen sHIelDIng specIFIcatIOns aRe Met. see sectIOn 6.3.
FOR HMF200 DO nOt Install IntO anY aRea HavIng a HeIgHt less tHan 7 Feet (2.13M). see
SECTIoN 6.3.
tHIs applIance, cOnFIguReD WItH all MODules, WeIgHs: HMF150 - 700lBs (318kg), HMF200 -
830lBs (375kg). ensuRe tHeRe Is aDeQuate FlOOR suppORt FOR tHe applIance.
tHe veRtIcal HeIgHt OF tHe aIR Intake lIneR Must nOt Be gReateR tHan 2/3 tHe HeIgHt OF
ThE ChIMNEy.
h3.34
do NoT dRAW oUTSIdE
AIR FRoM gARAgE SpACES. ExhAUST pRodUCTS oF gASoLINE
cOMBustIOn engInes aRe HazaRDOus.
do NoT dRAW oUTSIdE
aIR FROM attIc spaces, BaseMents OR aBOve tHe ROOFIng
WhERE oThER hEATINg AppLIANCES oR FANS ANd ChIMNEyS ExhAUST oR UTILIZE AIR.
tHese pRecautIOns WIll ReDuce tHe pOssIBIlItY OF applIance sMOkIng OR aIR FlOW
REvERSAL.
tHe OutsIDe aIR Inlet Must ReMaIn cleaR OF leaves, DeBRIs Ice anD/OR snOW. It Must
Be unRestRIcteD WHIle applIance Is In use tO pRevent cOMBustIOn aIR staRvatIOn
WHIcH can cause sMOke spIllage anD an InaBIlItY tO MaIntaIn a FIRe. sMOke spIllage
CAN ALSo SET oFF SMokE ALARMS.
NEgATIvE pRESSURE WIThIN yoUR hoME MAy INAdvERTENTLy AFFECT yoUR AppLIANCE.
eXHaust Fans sucH as BatHROOM Fans, Range HOODs anD clOtHes DRYeRs can
STRoNgLy INFLUENCE NEgATIvE pRESSURE IN ThE hoUSE.
aIR Inlet teRMInals Must Be InstalleD WItH aDeQuate gROunD cleaRance anD Be
SUFFICIENTLy ShIELdEd FRoM pREvAILINg WINdS To pREvENT FRoM REvERSINg IN ThE vENT
SySTEM.