Appliance smoking.
42.37_2
SYMPTOM
PROBLEM
TEST SOLUTION
-
Has the chimney had time to get
hot?
-
Is there adequate supply of
combustion air?
-
Is the outside air damper opened?
-
Is the smoke passage blocked
anywhere in the appliance or
chimney?
-
Is the smoke fl ow impeded by too
long of a horizontal pipe or too
many bends?
-
Is it a weak draft perhaps caused
by a leaky chimney, a cold outside
chimney, too short a chimney, or
a chimney too close to a tree or a
higher roof?
-
Bypass is closed while front door
is open .