W415-1517 / A / 09.02.16
21
EN
5.3
MINIMUM MANTEL CLEARANCES
MANTEL DIMENSIONS
Ref
Height
Depth
A
37 3/16” (945mm)
B
12” (305mm)
2"(51mm)
C
14” (356mm)
4"(102mm)
D
16” (406mm)
6"(152mm)
E
18”(457mm)
8"(203mm)
An optional combustible mantel must be a minimum of 12"(305mm) above the top of the faceplate and not to
extend more than 2"(51mm) from the surface. See chart below for further information.
MANTEL
HEIGHT
MANTEL
WIDTH
10
8
6
4
2
0
12
0
10
12
14
16
18
20
FACING, MANTEL AND / OR FINISHING MATERIALS MUST NOT INTERFERE WITH AIR FLOW THROUGH
AIR OPENINGS, LOUVRES, OPERATION OF LOUVRES OR DOORS OR ACCESS FOR SERVICE.