W415-1517 / A / 09.02.16
34
EN
INSTALL THE KB35 AND
BY-PASS SWITCHES IN A
CONVENIENT LOCATION
FAN
L2
L1
THERMODISC
G
FAN-SPEED CONTROL
(RHEOSTAT {VARIABLE SPEED SWITCH})
or WALL SWITCH or THERMOSTAT
NOT SUPPLIED
BY-PASS
(SUMMER)
SWITCH
NOT SUPPLIED
PRESSURE
SWITCH
GRILL
FILTER
ALLOW FOR
THICKNESS
OF FINISHING
MATERIAL
One black wire
- connects to power "L2"
(neutral lead).
One green wire
- connects to ground.
One white wire
- connects to the fan-
speed control, rheostat,
or wall switch,or thermo-
stat.
VENT CONNECTION
D.
Connect the 6"(152mm) liner to the 6"(152mm) appliance collar and blower collars. Secure using 3
screws on each end and seal with caulking. Liner stretches to a maximum of 10'(3m).
GRILL AND FILTER INSTALLATION
E.
Insert the fi lter into the grill. Foam gasket (
1
/
2
"(13mm) weather stripping) between the grill and blower
housing is recommended, but not supplied. The blower fi lter is washable. The bottom lip of the grill
latches over the bottom lip of the housing. Use two screws to secure the top of the grill to the facing.
NOTE: FOR COMPLETE INSTALLATION INSTRUCTIONS REFER TO THE BLOWER KIT.