GA-566 HOT AIR DISTRIBUTION KIT INSTALLATION INSTRUCTIONS

Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 0G8 Canada        •  1(866)820-8686         

 • www.napoleonfireplaces.com

W415-0151 / G / 11.29.17

!

WARNING

ENSURE THE APPLIANCE IS COMPLETELY COOL BEFORE STARTING INSTALLATION.

TO AVOID DANGER OF SUFFOCATION KEEP THE PACKAGING BAG AWAY FROM BABIES AND CHILDREN. DO 

NOT USE IN CRIBS, BED, CARRIAGES OR PLAY PENS. THIS BAG IS NOT A TOY. KNOT BEFORE THROWING 

AWAY.

This kit allows for warm air from an appliance to be vented 

into two separate locations within the home. It can also be 

used to direct hot air to the outside of the house, when used 

in conjunction with a Hot Air Exhaust Terminal (part #GA-72). 

This part may be ordered from your Wolf Steel authorized 

dealer. Directing heat to the outside of the building will re-

duce overheating a specific room, allowing the appliance to 

be enjoyed for a longer period of time. Where duct lengths 

are greater than 5 feet or when passing through uninsulated 

spaces such as an attic, it is recommended that the duct be 

insulated. An appliance may use up to two Hot Air Distribu-

tion Kits. 

WARNING: 

If the information in these instructions is not fol-

lowed exactly, a fire or explosion may result causing property 

damage, personal injury or death.

If this kit will be installed into the floor, a vent filter must be 

used to prevent any debris from falling into the blower.

1. 

Turn off any electrical power to 

fireplace.

2. 

Determine the desired location for 

the hot air discharge on the finished 

wall, keeping in mind that the blower 

housing must be centred between 

framing members. Cut a hole 

10

3

/

8

“ x  4½“, as illustrated, on the 

unfinished side of the opening. 

Attach the blower housing to the 

framing members ensuring that 

the off-centred hole in the finished wall matches the fan   

housing opening.

3. 

Determine the location for the variable speed switch. 

Attach an electrical box, not supplied, at this location.

4. 

Remove the knockout or cover plate from the fireplace. 

This could be located on the top, side or base of the unit, 

depending on the model of the fireplace and the connec-

tion point you require. 

10

3

/

8

” x 4½”

2

1

/

8

1½”

Blower 

Housing

Electrical Box /

Variable Speed 

Switch

Clamp

Duct

Adapter

Flange

Flexible 

Venting

Collar

Assembly

Fireplace

Junction

Box

Model NZ26:

 when installing the kit on this model, the 

collar assembly must be secured to the duct cover plate 

located on the base of the unit only.

Model GD70: 

when installing the kit on this model, using 

the top heat shield cover plate, the flexible duct must 

have a vertical rise only. Insulation and internal knock-outs 

must be removed when installing the kit using the top heat 

shield cover plate. When using the side heat shield cover 

plate discharge installation may be above or below the 

unit.

Secure the collar assembly over the opening using the 

screws supplied. 

Attach the venting to the collar assembly and secure using 

one of the ½” screws. At the other end attach the flexible 

venting to the duct adapter.  Clamp both ends. The complete 

hot air distribution kit requires zero clearance to combus-

tibles and should be adequately supported to avoid kinking.

5.

 Run a 14/2 electrical cable from the fireplace junction 

box to the wall mounted electical box and from the electri-

cal box to the blower assembly. In all cases it must be 

strain relieved and insulated when connecting to all electri-

cal junction boxes. Connect wiring at the blower assembly 

and the wall mounted electrical box.

6. For manual operations (non heat activated)

, wire the 

blower housing electrical box directly to the power source 

in series with the variable speed switch. See Method 1.