GEM-P816 Programming Instructions
Page 36
NAPCO Security Systems
R
RF RECEIVER & SUPERVISORY TIMER OPTIONS (ADDRESS 2029-2044 & 2056)
RF RECEIVERS:
Up to 2 RF Receivers may be pro-
grammed.
1. Select the number of receivers from the table
shown.
2. Enter number in address location shown.
3. Press
U
to save.
RF SUPERVISORY TIMERS:
RF Supervisory Timers may be programmed for each type of trans-
mitter used. A transmitter will send a transmission every time it is tripped, when there is NO activity,
the transmitter sends a status transmission about once an hour. If the receiver does NOT receive
ANY signal (a trip or a status) from a transmitter in the time specified for transmitter type, a system
trouble “
WIRELESS TROUBLE/E04-NN SERVICE
” will be displayed at the keypad.
1. Select timer delay from the table shown. Timers are programmed in increments of 30 minutes
each. Valid entries are [3] through [F] (90 minutes-450 minutes).
2. Enter in corresponding address locations below (right nibble).
3. Press
U
to save.
NOTE:
These timers apply only to Supervised RF Transmitters (see RF Transmitters in Easy Menu Driven Mode Programming).
DATA ENTRIES
blank (•)
None
1
1
2
2
RF RECEIVER(S)
Default for Number of Receivers
depends on Easy Menu Question for
RF Transmitters.
ADDRESS 2056
LEFT DIGIT
Number of RF
Receivers
RIGHT DIGIT
blank (•)
[Default = blank (•) from address 2029-2044]. Default = 8 (240 minutes)
RF SUPERVISORY
TIMER
RF TRANSMITTER
RF SUPERVISORY DELAY
TIME (Select timer delay
from the table at right)
Type 0
Window/Door, 2 Pt.
2029
Type 1
Window/Door, 2 Pt.
2030
Type 2
Window/Door, 2 Pt.
2031
Type 3
Window/Door, 2 Pt.
2032
Type 4
RESERVED
Type 5
PIR
2034
Type 6
PIR
2035
Type 7
Smoke Detector
2036
Type 8
Smoke Detector
2037
Type 9
RESERVED
Type A
Dual Tech.
2039
Type B
RESERVED
Type C
Window/Door, 4 Pt.
2041
Type D
PIR
2042
Type E
Smoke Detector
2043
Type F
Napco Glass Break
2044
ADDR
RF SUPERVISORY TIMERS
DATA ENTRIES
DELAY
3
90 min.
4
120 min.
5
150 min.
6
180 min.
7
210 min.
8
240 min.
9
270 min.
0
300 min.
B
330 min.
C
360 min.
D
390 min.
E
420 min.
450 min.
F
Содержание Gemini GEM-P816
Страница 18: ...GEM P816 Programming Instructions Page 18 NAPCO Security Systems R THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 31: ...NAPCO Security Systems R GEM P816 Programming Instructions Page 31 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 32: ...GEM P816 Programming Instructions Page 32 NAPCO Security Systems R THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 33: ...NAPCO Security Systems R GEM P816 Programming Instructions Page 33 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 34: ...GEM P816 Programming Instructions Page 34 NAPCO Security Systems R THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 35: ...NAPCO Security Systems R GEM P816 Programming Instructions Page 35 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 45: ...NAPCO Security Systems R GEM P816 Programming Instructions Page 45 NOTES...