ZONE OPTIONS - ZONES 1 TO 16 (ADDRESS 0900-1016) 

 

 

 

ZONES 1   8 

 

ZONES 9   16 

 

ZONE OPTIONS 

ADDR  Z1  Z2  Z3  Z4  Z5  Z6  Z7  Z8  ADDR  Z9  Z10  Z11  Z12  Z13  Z14  Z15  Z16 

 

 

 

 

 

50ms Loop Response (A) 

0900 

 

 

 

 

 

 

 

 

0964 

 

 

 

 

 

 

 

 

 

Priority 

0901 

 

 

 

 

 

 

 

 

0965 

 

 

 

 

 

 

 

 

 

Priority with Bypass 

0902 

 

 

 

 

 

 

 

 

0966 

 

 

 

 

 

 

 

 

 

Auto-Bypass 

0903 

 

 

 

 

 

 

 

 

0967 

 

 

 

 

 

 

 

 

 

Selective Bypass 

0904 

 

 

 

 

 

 

 

 

0968 

 

 

 

 

 

 

 

 

 

Keyswitch Arming 

0905 

 

 

 

 

 

 

 

 

0969 

 

 

 

 

 

 

 

 

 

Auto-Bypass Re-entry 

0906 

 

 

 

 

 

 

 

 

0970 

 

 

 

 

 

 

 

 

 

Pre-Alarm Warning 

0907 

 

 

 

 

 

 

 

 

0971 

 

 

 

 

 

 

 

 

 

Never Arm 

0908 

 

 

 

 

 

 

 

 

0972 

 

 

 

 

 

 

 

 

 

24-Hour Zone 

0909 

 

 

 

 

 

 

 

 

0973 

 

 

 

 

 

 

 

 

 

Alarm Output 

0910 

 

 

 

 

 

 

 

 

0974 

 

 

 

 

 

 

 

 

  

Pulsed Alarm Output 

0911 

 

 

 

 

 

 

 

 

0975 

 

 

 

 

 

 

 

 

 

PGM1 Output 

0912 

 

 

 

 

 

 

 

 

0976 

 

 

 

 

 

 

 

 

 

PGM2 Output 

0913 

 

 

 

 

 

 

 

 

0977 

 

 

 

 

 

 

 

 

  

Entry/Exit 1 

0914 

 

 

 

 

 

 

 

 

0978 

 

 

 

 

 

 

 

 

 

Entry/Exit 2 

0915 

 

 

 

 

 

 

 

 

0979 

 

 

 

 

 

 

 

 

  

Exit/Entry Follower 

0916 

 

 

 

 

 

 

 

 

0980 

 

 

 

 

 

 

 

 

 

Auto Reset 

0917 

 

 

 

 

 

 

 

 

0981 

 

 

 

 

 

 

 

 

 

Swinger Shutdown 

0918 

 

 

 

 

 

 

 

 

0982 

 

 

 

 

 

 

 

 

  

Chime 

0919 

 

 

 

 

 

 

 

 

0983 

 

 

 

 

 

 

 

 

 

Abort Delay 

0920 

 

 

 

 

 

 

 

 

0984 

 

 

 

 

 

 

 

 

 

Power-up Delay 

0921 

 

 

 

 

 

 

 

 

0985 

 

 

 

 

 

 

 

 

 

Day Zone Open 

0922 

 

 

 

 

 

 

 

 

0986 

 

 

 

 

 

 

 

 

 

Day Zone Short 

0923 

 

 

 

 

 

 

 

 

0987 

 

 

 

 

 

 

 

 

 

Alarm on Day Zone 

0924 

 

 

 

 

 

 

 

 

0988 

 

 

 

 

 

 

 

 

  

Alarm Telco 1 

0925 

 

 

 

 

 

 

 

 

0989 

 

 

 

 

 

 

 

 

 

Alarm Restore 1 

0926 

 

 

 

 

 

 

 

 

0990 

 

 

 

 

 

 

 

 

 

Trouble Telco 1 

0927 

 

 

 

 

 

 

 

 

0991 

 

 

 

 

 

 

 

 

 

Trouble Restore 1 

0928 

 

 

 

 

 

 

 

 

0992 

 

 

 

 

 

 

 

 

 

Alarm Telco 3 

0929 

 

 

 

 

 

 

 

 

0993 

 

 

 

 

 

 

 

 

 

Alarm Restore 3 

0930 

 

 

 

 

 

 

 

 

0994 

 

 

 

 

 

 

 

 

 

Trouble Telco 3 

0931 

 

 

 

 

 

 

 

 

0995 

 

 

 

 

 

 

 

 

 

Trouble Restore 3 

0932 

 

 

 

 

 

 

 

 

0996 

 

 

 

 

 

 

 

 

 

No EOL Resistor 

0933 

 

 

 

 

 

 

 

 

0997 

 

 

 

 

 

 

 

 

 

Trouble on Open 

0934 

 

 

 

 

 

 

 

 

0998 

 

 

 

 

 

 

 

 

 

Trouble on Short 

0935 

 

 

 

 

 

 

 

 

0999 

 

 

 

 

 

 

 

 

  

Zone Area 1 

0936 

 

 

 

 

 

 

 

 

1000 

 

 

 

 

 

 

 

 

 

RESERVED 

0937 

 

 

 

 

 

 

 

 

1001 

 

 

 

 

 

 

 

 

  

RESERVED

 

0938 

 

 

 

 

 

 

 

 

1002 

 

 

 

 

 

 

 

 

 

Keypad Sounder on Alarm 

0941 

 

 

 

 

 

 

 

 

1005 

 

 

 

 

 

 

 

 

  

2-Wire Smoke Detectors (B) 

0942 

 

 

 

 

 

 

 

 

1006 

 

 

 

 

 

 

 

 

  

Fire (C) 

0943 

 

 

 

 

 

 

 

 

1007 

 

 

 

 

 

 

 

 

 

Fire Alarm Verification (C) 

0944 

 

 

 

 

 

 

 

 

1008 

 

 

 

 

 

 

 

 

 

RESERVED 

0945 

 

 

 

 

 

 

 

 

1009 

 

 

 

 

 

 

 

 

 

Zone ANDing Group 1 

0946 

 

 

 

 

 

 

 

 

1010 

 

 

 

 

 

 

 

 

 

Zone ANDing Group 2 

0947 

 

 

 

 

 

 

 

 

1011 

 

 

 

 

 

 

 

 

 

Zone ANDing Group 3 

0948 

 

 

 

 

 

 

 

 

1012 

 

 

 

 

 

 

 

 

 

Zone ANDing Group 4 

0949 

 

 

 

 

 

 

 

 

1013 

 

 

 

 

 

 

 

 

 

Sensor Watch 

0950 

 

 

 

 

 

 

 

 

1014 

 

 

 

 

 

 

 

 

 

RESERVED 

0951 

 

 

 

 

 

 

 

 

1015 

 

 

 

 

 

 

 

 

 

Chime 2 

0952 

 

 

 

 

 

 

 

 

1016 

 

 

 

 

 

 

 

 

  

When the Easy Program Menu is used, these features are enabled by default. 

  

Enabled when "Enable SIA CP-01 Features?" is activated (Answer "Yes" in the EZ Programming Menu). 

  

Disabled when "Enable SIA CP-01 Features?" is activated (Answer "Yes" in the EZ Programming Menu).  Disable Auto-Reset on non-fire zones for SIA CP-01 installations. 

 

Interior (Stay) Bypass 

0940 

 

 

 

 

 

 

 

 

1004 

 

 

 

 

 

 

 

 

 

RESERVED

 

0939 

 

 

 

 

 

 

 

 

1003 

 

 

 

 

 

 

 

 

 

RESERVED 

0953 

 

 

 

 

 

 

 

 

1017 

 

 

 

 

 

 

 

 

 

RESERVED 

0954 

 

 

 

 

 

 

 

 

1018 

 

 

 

 

 

 

 

 

ZONE OPTIONS:

 Select zone options for any zone. 

1.      Select the desired zone option by entering the option number (1-8) for each selected zone. 

2.      Enter corresponding option number in address location. 

NOTE:

  Dark shaded data value box shows option not available.  Press [Enter] to save. 

Notes A, B and C are 
located on the next 
page. 

Содержание Gemini GEM-P816

Страница 1: ...de Quick Start for K Series GEM K1CA 1 Refer to the wiring diagram connect Siren Aux Power PGM Output Remote Bus Earth ground Zone and Tele phone wiring NOTE See Installation Instructions WI994 2 Conn...

Страница 2: ...he A button and the R button operate identically in Program Mode for both keypads The D button and the U button operate identically in Program Mode for both keypads The button and the button operate i...

Страница 3: ...tion Receiver 1 Format 8 Enter User Codes 8 RF Transmitter Points 9 Keyfob Transmitters as Arm Disarm Control Devices 9 Keyfob Transmitters as Zone Input Devices 10 Enter Zone Descriptions 10 Enter Da...

Страница 4: ...ode is an extension of the Dealer Program Mode wherein data is entered at the keypad by location This mode is accessed from the Easy Menu Driven Program Mode by pressing the C button at any time User...

Страница 5: ...1 24 Hour Zones in Area 1 Chime Zones in Area 1 Chime 2 Zones in Area 1 Exit Entry2 Zones in Area 1 50mS Loop Response Zones Note 750mS is re quired for Loop Response time in UL installations Aux Outp...

Страница 6: ...zones which have been designated as Fire Zones can be programmed as 2 Wire Fire zones JP3 must be set to 2 WF position for 2 wire fire refer to Installation Instruc tions Local or Central Station Rep...

Страница 7: ...er each zone number including leading zeros Press U to save then repeat for any additional zone s Press the NEXT YES button to proceed NOTE A PGM2 Timeout of 15 minutes will automatically be programme...

Страница 8: ...blank Press G1 through G4 for letters B E Press U to save press the NEXT YES button to proceed Enter User Codes Press R to set cursor For default program enter up to 16 User Codes with Area 1 Options...

Страница 9: ...been programmed Transmitter 287613 1 point 1 will be mapped to Zone 6 5 Enter Zone 09 6 Close point 1 loop and open point 2 loop 7 Remove the transmitter battery then re install it The keypad will bee...

Страница 10: ...s the NEXT YES button to proceed Dealer Code Directly enter the Dealer Code default 456789 using 0 through 9 buttons Press U to save Re enter the Dealer Code to verify the previous code Press U to sav...

Страница 11: ...ay and accept data in number format For example Zone Features are turned on by the pressing of keypad buttons 1 through 8 with the activated Zone s displaying the corresponding decimal digit replacing...

Страница 12: ...or automatically moving to the right upon each key press EXAMPLE DECIMAL Format with the GEM RP1CAe2 Program Abort Delay to be 15 seconds DETERMINE THE DATA ENTRIES 1 Referring to SYSTEM DELAYS TIMEOU...

Страница 13: ...ferring to SYSTEM DELAYS TIMEOUTS in the Programming Worksheets that follow the Chime Timeout is located at address 1418 In the Chime Timeout Options table the data entries needed to assign a time out...

Страница 14: ...lowing any keypad programming and that the PCD Windows s error check feature be utilized to reduce the possibility of programming omissions or conflicts 3 Keep the Keypad Programming Worksheets on fil...

Страница 15: ...1418 1419 DEFAULTS The defaults shown on this page and on the following pages are automatically set after exiting the Easy Menu Driven Mode 1 Enter delay timeout in corresponding address locations abo...

Страница 16: ...ADDRESS 0546 0547 LEADING DIGITS FOR PAGER FORMAT In Pager Format reporting the message typically begins with 00 However for some pager services this will cause the Pager s Voice Mail feature to acti...

Страница 17: ...code If Enable Global Ambush Code Address 1422 is selected and Address 2045 is left blank then the 2 digit Global Ambush Code is 99 If Enable Global Ambush Code is se lected and Address 2045 is not le...

Страница 18: ...GEM P816 Programming Instructions Page 18 NAPCO Security Systems R THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 19: ...ouble Activates Telco 3 OFF 4 Enable Residential Fire OFF 4 Enable Alarm Output on Telco Fail only when Armed OFF 5 Disable Keypad Function Mode Download OFF 5 Line Fault Test only when Armed OFF 6 Di...

Страница 20: ...re location Default for CS Receiver 1 Tele phone Number depends on Easy Menu Question C E N T R A L PHONE Default blank across digits 1 20 for CS Receiver Telephone Num bers 2 and 3 ADDRESS 0460 CS Re...

Страница 21: ...GITS 1 4 0576 0577 0578 0579 CS Telco 1 Sub scriber Opening Closing ID Number Area 1 ADDRESS 0560 0563 RIGHT DIGITS 1 4 0560 0561 0562 0563 CS Telco 2 Sub scriber Event ID Number Area 1 ADDRESS 0612 0...

Страница 22: ...CS SYSTEM REPORTING OPTIONS ADDRESS 0670 0705 CS AREA SYSTEM REPORTING OPTIONS ADDRESS 0785 0786 0788 Default blank blank DISABLE OPENING REPORTS LEFT DIGIT RIGHT DIGIT SUM OF DATA VALUES blank ADDRES...

Страница 23: ...16 0732 0733 0734 0735 PULSE EVENT CODE will be the first digit of the 2 digit reporting code The second digit will be the second digit of the reporting zone For example for zone 9 address 0728 if th...

Страница 24: ...n entering the option number 1 8 for each digit 2 At the keypad enter corresponding option number in address location NOTE Dark shaded data value box shows option not available 3 Press U to save USERS...

Страница 25: ...ZM mod ules are connected Each Group represents 4 Zones 1 Select EZM type from the table shown 2 Enter either blank or 1 in corresponding address locations above 3 Press U to save EZM GROUP OPTIONS AD...

Страница 26: ...IONS ADDRESS 1473 1477 1481 1485 1481 PGM1 Output Turns Off upon Disarm Default Option Disarming ON 1 PGM1 Output Silenced OFF 2 RESERVED 1485 PGM2 Output Turns Off upon Disarm Default Option Disarmin...

Страница 27: ...Keypad Area Assignment KEYPAD TYPE Up to 7 key pads may be programmed if they are connected NOTE See Keypad Configura tion Mode 1 Select keypad type for each keypad from the tables shown 2 Enter data...

Страница 28: ...eated for temperature out of limits and restore If the G key is depressed and held down for 2 seconds the date will display for 5 seconds In addition three addresses must be enabled either via Quicklo...

Страница 29: ...lco 3 0931 0995 Trouble Restore 3 0932 0996 No EOL Resistor 0933 0997 Trouble on Open 0934 0998 Trouble on Short 0935 0999 Zone Area 1 0936 1000 RESERVED 0937 1001 RESERVED 0938 1002 Keypad Sounder on...

Страница 30: ...e Bypass Alarm Output Auto Reset Swinger Shutdown and Zone Area 1 are enabled for the total number of zones entered in OF ZONES IN AREA1 ENTER ZONES Alarm Telco 1 is enabled for the zone number s ente...

Страница 31: ...NAPCO Security Systems R GEM P816 Programming Instructions Page 31 THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 32: ...GEM P816 Programming Instructions Page 32 NAPCO Security Systems R THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 33: ...NAPCO Security Systems R GEM P816 Programming Instructions Page 33 THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 34: ...GEM P816 Programming Instructions Page 34 NAPCO Security Systems R THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 35: ...NAPCO Security Systems R GEM P816 Programming Instructions Page 35 THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 36: ...Enter in corresponding address locations below right nibble 3 Press U to save NOTE These timers apply only to Supervised RF Transmitters see RF Transmitters in Easy Menu Driven Mode Programming DATA...

Страница 37: ...ures schedules can only be programmed again with the Downloading Software If power fails time and date restarts at 00 00 00 and a date of 01 01 04 January 1 2004 2285 XX H 2286 XX H USER PROGRAM MODE...

Страница 38: ...de if any Enter the new User Code using the number buttons 0 9 If an old code is displayed program over it To erase the digit at the cursor press G 0 button Press the U button to save the code in memo...

Страница 39: ...to uppercase Press U to save To advance to the next zone or to any other zone move the cursor to the displayed zone number i e 01 using R and B Change the zone number using keys 0 through 9 Enter two...

Страница 40: ...ad Each GEM RP1CAe2 GEM K1CA keypad must be configured for a keypad tactile beep b entry sounder c keypad address d compatibility number e EZM address and f zone response To enter the Keypad Configura...

Страница 41: ...s the C button to exit Zone Response The normal loop response of each keypad expansion zone is 750mS how ever the response time of any zone can be reduced to 50mS as follows 1 Of the following circle...

Страница 42: ...ntry Exit Zones 1 16 __________ Enter Interior Zones 1 16 __________ Report all Zones to Central Yes No Central Station Receiver 1 Telephone Number Central Station Receiver 1 Account Number Central St...

Страница 43: ...age 43 EASY MENU PROGRAMMING WORKSHEET 2 OF 3 RF Transmitter Points XMTR ZONE CHECK SUM POINT 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 RF ID printed on xmtr box Keyfob Transmitters KEYFOB Area CHECK SUM...

Страница 44: ...N 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 CHARACTERS AVAILABLE See below 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 Dealer Code Characters Available for Zone Descript...

Страница 45: ...NAPCO Security Systems R GEM P816 Programming Instructions Page 45 NOTES...

Страница 46: ...ONE OPTION ADDRESS 0929 0993 29 AMBUSH AREA OPTION 9 AMBUSH ADDRESS 0698 22 AREA BELL CONTROL OPTIONS ADDRESS 1473 1485 26 ARM ONLY AREA OPTION 9 ARM DISARM AREA OPTION 9 AUTO BELL TEST ON ARMING ADDR...

Страница 47: ...85 22 DISABLE SYSTEM TROUBLE AUDIBLE TIMEOUT ADDRESS 2051 19 DISABLE WAIT FOR HANDSHAKE ON TRANSMIT ADDRESS 0788 22 DISABLE WAIT FOR SILENCE PAGER FORMAT ADDRESS 0788 22 DISABLE ZONE FAULT SCROLLING A...

Страница 48: ...KEYPAD OPTIONS ADDRESS 1425 1431 1440 1446 27 KEYPAD SOUNDER ON ALARM ZONE OPTION ADDRESS 0941 1005 29 KEYPAD SOUNDER ON ALARM ZONES 7 KEYPAD TACTILE BEEP 40 KEYSWITCH ARMING ZONE OPTION ADDRESS 0905...

Страница 49: ...0 19 SUM CHECK ADDRESS 0461 20 SUM CHECK ADDRESS 0483 20 SUM CHECK ADDRESS 0505 20 SUPPRESS BYPASS REMINDER WHEN ARMED ADDRESS 1421 19 SWINGER SHUTDOWN ZONE OPTION ADDRESS 0918 0982 29 SYSTEM DELAYS T...

Страница 50: ...OPTION ADDRESS 0946 1010 29 ZONE ANDING GROUP 2 ZONE OPTION ADDRESS 0947 1011 29 ZONE ANDING GROUP 3 ZONE OPTION ADDRESS 0948 1012 29 ZONE ANDING GROUP 4 ZONE OPTION ADDRESS 0949 1013 29 ZONE AREA 1...

Страница 51: ...ELCO 2 20 ADDRESS 0483 ENABLE ZONE NUMBER ON PULSE ALARM 20 ADDRESS 0483 SINGLE DIGIT ONLY 20 ADDRESS 0483 SUM CHECK 20 ADDRESS 0483 ENABLE TCP IP AES RPT 20 ADDRESS 0484 0503 CS RECEIVER 2 TELEPHONE...

Страница 52: ...ADDRESS 0704 FAIL TO CLOSE 22 ADDRESS 0705 KEYFOB LOW BATTERY 22 ADDRESS 0720 0735 CS ZONE REPORTING OPTIONS 23 ADDRESS 0785 CS AREA SYSTEM REPORTING OPTIONS 22 ADDRESS 0785 DISABLE OPENING REPORTS 2...

Страница 53: ...ADDRESS 1418 CHIME TIME 15 ADDRESS 1418 1419 SYSTEM DELAYS TIMEOUTS 15 ADDRESS 1419 AC FAIL REPORT DELAY 15 ADDRESS 1420 CLOSING REPORT ONLY ON CONDITIONAL CLOSE 19 ADDRESS 1420 DISABLE ZONE FAULT SC...

Страница 54: ...ESS 1425 1431 ENABLE KEYPAD TYPE ACTIVATION 27 ADDRESS 1425 1431 KEYPAD OPTIONS 27 ADDRESS 1440 1446 ENABLE KEYPAD OPTIONS 27 ADDRESS 1440 1446 KEYPAD OPTIONS 27 ADDRESS 1455 1456 EZM GROUP OPTIONS 25...

Страница 55: ...SS 2053 ENABLE KEYPAD 1 ONLY PROGRAMMING 19 ADDRESS 2053 EXIT TIME RESTART 19 ADDRESS 2053 RPT EXIT ERR RECENT CLOSE 19 ADDRESS 2053 SOUND ALARM ON EXIT ERROR 19 ADDRESS 2054 ENABLE TCP IP COMMUNICATI...

Страница 56: ...GEM P816 Programming Instructions Page 56 NAPCO Security Systems R GEM P816 WIRING DIAGRAM Smoke Detector Compatibility Identifier GEM P816...

Отзывы: