GEM-P816 Programming Instructions
Page 10
NAPCO Security Systems
R
Keyfob Transmitters as Zone Input Devices
(Refer to display above: press the AWAY button to go backwards).
Each of the 4 keyfob buttons can be assigned to a zone. For example, On button = point 1; Off button =
point 2; A1 = point 3; A2 = point 4. Up to 16 keyfobs (using 1 button) or 8 keyfobs (using 2 buttons) or 4
keyfobs (using all 4 buttons) or any combination up to a maximum of 16 controlled zones can be assigned,
providing multiple wireless panic buttons on a system, each reporting to a Central Station or a pager and/or
annunciating on a keypad the keyfob zone number with a description.
To assign a keyfob to a zone:
pro-
gram the keyfob as you would a transmitter, entering the keyfob's ID code, check sum and point number at
the appropriate zone. The “Quick Method” is not allowed. The zone may be hardwired to an electrical
sensor as well as assigned to a keyfob (either one will activate the zone alarm output).
NOTE:
If assigning
a keyfob to a zone, the “ON/OFF” buttons on the keyfob will no longer arm/disarm the system. The keyfob
is converted to a “panic only” device.
Enter Zone Descriptions
•
For each zone, enter a description of up to two lines. Press
U
to save each description.
•
See page 41 for instructions for entering characters and numbers for the zone descriptions.
•
To proceed to the next description, place the cursor under the Zone Number (e.g. “1”) and
press the number that corresponds to the zone. Program new description as above.
NOTE:
Zone Descriptions can only be entered through the
GEM-RP1CAe2 Keypad or by using the Napco Quickloader Software.
See
Easy Menu Programming Worksheet
for available zone description characters.
Enter Date
(Press
R
to set cursor).
•
Enter the current date in the format MM/DD/YY. (MM = month, DD = day and YY = year.
•
Press
U
to save. Press the NEXT/YES button to proceed.
Enter Time
(Press
R
to set cursor.)
•
Enter the current time in format HH:MMA/P, where HH=hours (01–12); MM=minutes (00–59).
•
Select AM or PM by pressing any number button.
•
Press
U
to save. Press the NEXT/YES button to proceed.
Dealer Code
•
Directly enter the Dealer Code (default = 456789), using
0
through
9
buttons.
•
Press
U
to save. Re-enter the Dealer Code to verify the previous code. Press
U
to save.
•
Press the NEXT/YES button to proceed.
Test Timer
•
Select day(s) by simply erasing the unwanted days. Move the cursor over the day and
press any number key to erase/restore the day. For example, "Monday" and "Friday" will
appear as: "•
M
•
•
•
F
•"
•
Enter Time (in 24 hour format) by moving cursor under the left H and pressing two digits to over-
write the existing default of 00.
Note:
Midnight is 00:00. Enter minutes by continuing to enter
data or if just updating minutes move the cursor under the left M and enter the two digits to over-
write the existing default of 00. Use
R
as right cursor one position.
(Direct Entry)
Enter Date
( / / )
(Direct Entry)
Enter Time
( : )
D e a l e r C o d e
4 5 6 7 8 9
D E A L E R C O D E
R E - E N T E R
CLEAR PROGRAM:
Should it be necessary to create a new custom default program, (a) from the Dealer Program Mode, press
C
to enter the Address Program Mode; (b) access Location 2285 (Clear Program) or 2286 (Cold Start); (c) press
U
and then
(d) press
C
to exit the Dealer Program Mode. A “
SYSTEM TROUBLE/E09-00 SERVICE
” will occur. Press
C
to silence the keypad.
Clear Dealer Program (Erases Dealer Program)
Use this feature to erase the Panel Program, while maintaining Scheduled Data and Zone Descrip-
tions. Access address 2285 and press
U
. Data entry is not allowed.
NOTE:
Enter Easy
Menu Driven Program Mode to reprogram system.
Cold Start (Erases Entire Program)
This erases all programmed data (Dealer Program, Zone Description Data and Schedules).
Access address 2286 and press
U
. Data entry is not allowed.
NOTE:
Some features
(schedules) can only be programmed again with the Downloading Software.
DATA
ENTRY
AUX 1/AUX 2
OPTIONS
0
None
1
Relay Group 1 Toggle
2
Relay Group 2 Toggle
9
Keypad Panic
A
Keypad Aux.
B
Instant
C
PGM2 Ouput Toggle
D
Access on PGM2 Output
E
Arm STAY
F
Interior Button
(Direct Entry)
0 1 -
EXIT DEALER PROGRAM MODE:
This completes the custom default program. Press
C
to enter the Direct Address Program
Mode for further programming or press
C
once again to end all programming and resume normal keypad operation.
2 2 8 5 X X H
2 2 8 6 X X H
T E S T T I M E R
S M T W T F S H H : M M
Содержание Gemini GEM-P816
Страница 18: ...GEM P816 Programming Instructions Page 18 NAPCO Security Systems R THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 31: ...NAPCO Security Systems R GEM P816 Programming Instructions Page 31 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 32: ...GEM P816 Programming Instructions Page 32 NAPCO Security Systems R THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 33: ...NAPCO Security Systems R GEM P816 Programming Instructions Page 33 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 34: ...GEM P816 Programming Instructions Page 34 NAPCO Security Systems R THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 35: ...NAPCO Security Systems R GEM P816 Programming Instructions Page 35 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 45: ...NAPCO Security Systems R GEM P816 Programming Instructions Page 45 NOTES...