mychefcooking.com
PRODUCT MANUAL BAKERSHOP - DT.MP.BS.2103.2
51
Table 13. Periodic maintenance table
Regular maintenance ensures that your oven always works as designed.
Periodic maintenance must be accredited for warranty validity purposes.
Before any handling for maintenance or repair, the equipment must be
disconnected from the power supply.
If the power cable is damaged, it must be replaced by your service
department or similarly qualified personnel in order to avoid risks.
Mychef maintenance program
2000 4000 6000 8000 10000 12000 14000 16000 18000 20000
Review A
Firmware upgrade
X
X
X
X
X
X
X
X
X
X
Water hardness test
X
X
X
X
X
X
X
X
X
X
Cleaning of cooling fans
X
X
X
X
X
X
X
X
X
X
Electronic cleaning
X
X
X
X
X
X
X
X
X
X
Cleaning drainage tray and siphon
X
X
X
X
X
X
X
X
X
X
Changing the gasket and adjusting the door
X
X
X
X
X
X
X
X
X
X
Review B
Pathogen-inactivated replacement (depending on model)
X
X
X
X
X
Calibration of temperatures
X
X
X
X
X
Adjustment of internal screws
X
X
X
X
X
Review C
Change of chimney and drain pipes
X
X
Change of electrovalve for steam generation
X
X
Change of resistance contactor (only models without TSC)
X
X
Review D
Change of motor
X
Change of resistance and gasket
X
Cambio of internal gaskets
X