mychefcooking.com
PRODUCT MANUAL BAKERSHOP - DT.MP.BS.2103.2
27
6.3.
Errors and alarms
Errors and alarms can occur during the preparation and execution of cooking or washing
processes. If this is the case, the central display will show the error or alarm code.
Figure 21. Error indicator
The table below shows the various errors and alarms, as well as possible solutions to them:
Error
Internal definition
Clarification
0
NO ERROR
No error.
1
ERROR GENERAL PURPOSE INPUT Reserved. Not used.
2
ERROR OVERTEMPERATURE
Reserved. Not used.
3
ERROR OVERTEMPERATURE PCB
Overtemperature PCB. Check that the electronics'
cooling fans are working properly, that there is
enough space between the rear part and the wall,
and that the ambient temperature is not excessive.
4
ERROR COMMUNICATION
Inter-board communication not responding.
Check the cable between the power board and
the control board.
5
ERROR EEPROM
Processor communication and EEPROM not
working. Check the control board.
6
ERROR MOTOR
Engine error. Check the motor wiring.
Overtemperature in the engine. Engine nailed
down.
7
ALARM WATER
Reserved. Not used.
8
ERROR WASHING
Reserved. Not used.
9
ERROR PROBE1 TEMP SENSOR
NOT CONNECTED
Reserved. Not used.
10
ERROR PROBE1 TEMP SENSOR
SHORTED
Reserved. Not used.
11
ERROR PROBE2 TEMP SENSOR
NOT CONNECTED
Reserved. Not used.
12
ERROR PROBE2 TEMP SENSOR
SHORTED
Reserved. Not used.