This book contains all the necessary fitting and operating instructions for your MX 

thermostatic concentric mixer shower.

Please read these instructions carefully. Read through the whole of this book before

beginning your installation. 

The shower installation 

MUST

 be carried out by a suitably competent person after reading 

these instructions.

Care taken during the installation will provide a long and trouble free life from your shower. 

For the best performance within the specified running pressure range, a minimum flow of 

5 liters per minute should be available on both inlets.

This mixer valve is designed to operate on higher pressure systems found up to a maximum 

of 5 bar running pressure. The valve must not be subjected to water temperatures above 

80°C. This mixer is also suitable for thermal storage, unvented systems and pumped  

gravity systems.

IMPORTANT: Before installing with a gas instantaneous water heater, make sure it is 

capable of delivering hot water at a minimum switch-on flow rate of 3 liters per minute. 

At flow rates between 3 and 8 liters per minute, the appliance must be capable of raising the 

water temperature to a minimum of 52°C.

The water temperature at the inlet to the mixer valve must remain relatively constant when flow 

rate adjustments are made (refer to the water heater operating manual to confirm compatibility 

with this mixer shower).

Inlet connections are to 15mm compression fittings.

SAFETY WARNINGS 

Layout and sizing of pipework must be such that when other services are used, pressures at the 

shower control inlets do not fall below the recommended minimum.

DO NOT choose a position where the shower could become frozen or connect this mixer valve 

to any form of tap or fitting not recommended by the manufacturer.

The showerhead must be regularly cleaned to remove scale and debris.

Conveniently situated service valves in each inlet supply must be fitted as an independent 

method of isolating the shower should maintenance or servicing be necessary, these valves 

should not restrict the flow.

DO NOT operate the shower outside the recommended temperatures and pressures stated in 

this guide.

As a competent person installing this shower you should ensure that all users are very 

conversant in its operation. Always test the water temperature with you hand before entering 

the shower.

Содержание Atmos Zinc

Страница 1: ...Thermostatic Concentric Mixer Valve with Fixed Head Wall Arm Atmos Zinc Thermostatic Concentric Mixer Valve with Fixed Head Wall or Ceiling Arm Customer Care 0845 505 2211 TMV2 Approval property of T...

Страница 2: ...8 liters per minute the appliance must be capable of raising the water temperature to a minimum of 52 C The water temperature at the inlet to the mixer valve must remain relatively constant when flow...

Страница 3: ...a point not less than 25mm above the spill over level of the relevant bath shower tray or other fixed appliance A double check valve or similar MUST be fitted in the supply pipework to prevent back fl...

Страница 4: ...hot and cold water pressures If this is not the case a flow controller disc with small holes can be fitted to the higher pressure supply to the valve This is best done by testing each one to find out...

Страница 5: ...th Wall Arm Atmos Zone Concealed Valve with Wall Arm Atmos Zinc Concealed Valve with Ceiling Arm Atmos Zinc Consult the illustration below to make sure you check from the component list that all the p...

Страница 6: ...water pressures to hot and cold are the same these disks do not need to be used CONCENTRIC VALVE SET UP 1 Your thermostatic concentric mixer valve is set up in the factory so that a shower hose can be...

Страница 7: ...getting into the openings while fitting the pipework You should measure the distance between the outlets on the mixer valve you are fitting to determine the exact distance 3 Complete the fitting of t...

Страница 8: ...nnecting the water supplies and checking the connections when running the shower and when the shower is off TRIM PLATE FITTING FOR Atmos Zinc Zone 1 The trim plate is fitted by pushing it onto the mix...

Страница 9: ...arm drill a suitable 19mm hole through the wall NOTE When fitting to stud wall a bearer between the uprights maybe required 3 Remove fittings and nuts from end of arm and push arm through wall re fit...

Страница 10: ...fit a cross bearer between two joists Drill suitable 19mm hole through ceiling See Fig 23 3 Remove fittings and nuts from end of arm and push arm through wall re fit washer and nut 4 Connect mixed wat...

Страница 11: ...ew Then turning the splined shaft clockwise to decrease the temperature colder or anti clockwise to increase the temperature hotter when you have achieved a temperature of 38 C re assemble the tempera...

Страница 12: ...the heating system F Hot water supply blocked or restricted G Pressure in excess of max recommended SUGGESTED ACTION Adjust the temperature control this is only a job for a suitably qualified person T...

Страница 13: ...Showerhead Reduce simultaneous demand Check stop service valves are fully open Check if enough water pressure Fit reducing disc to outlet of valve Renew flow control cartridge see parts list COMPONEN...

Страница 14: ...IT SPARE PARTS Atmos Zinc 1 Fixed Overhead ZLK 2 Wall Arm ZLJ 3 Ceiling Arm ZLI 4 Valve only 36HLW ZLD VALVE SPARE PARTS LIST 5 Fitting Kit 36HLW ZJK 6 Cartridge All in one ZJA 7 Square Cover Plate ZJ...

Страница 15: ...14 ACCESSORIES KIT SPARE PARTS Atmos Zone 1 Fixed Overhead ZLS 2 Valve only 36HLW ZLG VALVE SPARE PARTS LIST 3 Fitting Kit 36HLW ZJK 4 Cartridge all in one ZJA 5 Cover Cover Plate ZJV 1 2 3 4 5...

Страница 16: ...hout charge provided the product has been properly installed maintained and operated in accordance with the operating instructions This product must not be modified repaired or taken apart except by a...

Страница 17: ...5 This guarantee applies to an original installation in accordance to our fitting instructions and does not cover previously installed products showroom displays etc or products that have been moved f...

Страница 18: ...our part for death or personal injury resulting from our negligence 4 Except as stated above and to the fullest extent permitted by law all conditions warranties and representations whether express o...

Страница 19: ...e on parts or products not supplied as part of the product 4 A charge will be made in the event of a service call aborted by you but not by us or where a call under the terms of guarantee has been boo...

Страница 20: ...Cross Limited Trading as The MX Group Alpha Close Delta Drive Tewkesbury Industrial Estate Tewkesbury Glos GL20 8JF www mx group com email mixervalves mx group com Customer Care 0845 505 2211 6752A 0...

Отзывы: