9
Fig. 4 Top View
Fig. 5 Front View
Before connecting the drain and water supply hoses,
check the following:
The drain hose must drop a 1/4" for every foot in length
to allow for adequate draining.
An air gap is required between the drain hose and the
floor drain to prevent backflow into the ice storage bin.
Important Information :
Incorect drain installation will
cause ice in the bin to melt due to excessive water.
1)Arrange the ice maker at the front of the opening of
installation.
2)Adjust the feet to the correct height.
3)Install the inlet pipe (1/4" diameter copper tubing or
flexible rubber hose)and connect to the water supply
valve.Connect the water supply to the ice machine after
purging the water line to make sure the water is free
from any particles or debri.
4)If the electric outlet is at the back of the product, insert
the plug in the electric outlet.
5)Install the product so that the front of the product is
facing forwards.
6)Use the inlet pipe after cutting it to the required length.
7)Cut the required length of drain hose.
8)Connect the drain nipple (with a diameter of 3/4” FPT)
9)Turn on the tap and check for any leakage.
10) Make sure the product is level.
Gravity Drain Model
Water Filter
Shut-Off Valve
MIN. 15¼"(387)
2
4
"(610)
0.16(4)
0.16(4)
Drain Tube
Water Inlet Tube
Locate drain
within 2" DIA.
Area 23" back from
front of unit
M
IN
(857)