5.4 PERIODICAL SERVICES FOR AUTHORISED MUTOH
TECHNICIAN
This section describes the periodical services required for this machine. The periodical services ensure
stable printout quality of the machine. In the periodical services, some service parts may be checked,
cleaned, or replaced.
Caution
•
There are two parts of periodical service, namely the parts that can be replaced by the end-user
and the parts that need to be done by authorized Mutoh technicians.
(1) Periodical inspections
Cycle Servive by authorised Mutoh technician
frequency
1
APPLY GREASE ON HEAD UP-DOWN CAMMS
if needed
2
APPLY GREASE ON Y-MOTOR BELT
if needed
3
APPLY GREASE ON ROLLER PATH CARRAIGE
if needed
4
APPLY GREASE ON CAPPING STATION CAMM + GEARS
if needed
5
Replace all caps
Every 3 months
6
Replace the tubes connecting the pumps to waste bottle
Every 3 months
7
CHECK Cylinder Supporting bearings
every 6 months
8
CHANGE PUMPS
every 6 months
9
CHECK and RELACE when necessary SPITTING BOX RIGHT + TUBE + L
CONNECTION
every 6 months
10
CHANGE DAMPERS
every year
11
CHANGE MAINTENANCE STATION
every year
(2) Parts needed
Cycle
Parts needed
1 Grease
2 Grease
3 Grease
4 Grease
5 ME-80077
6 4x0,8m
ME-18280
7
4 x MY-41405
8
1 x MY-35085+ 1m ME-80385+ 1 x ME-60014
9
16 x MY-42110
10 4x0,8m
ME-18280
11
1 x KY-80627
Notes
•
All cleaning in “Ink areas” must be done with Mutoh water based textile cleaning liquid.
•
Above maintenance cycle is based on use:
8 hours / day, 5 days / week, 44 weeks / year.
If machine is used more, maintenance periods will come earlier.