![MULTIQUIP DCA400SSI4F Скачать руководство пользователя страница 62](http://html.mh-extra.com/html/multiquip/dca400ssi4f/dca400ssi4f_operation-manual_1855182062.webp)
PAGE 62 — DCA400SSI4F/DCA400SSI4F3 60 HZ GENERATOR • OPERATION MANUAL — REV. #3 (04/18/22)
MAINTENANCE
HOW TO ACTIVATE ESCAPE MODE
If the ECU displays any messages referenced in Table 15,
it may be necessary to restart via ESCAPE MODE.
Starting
1. Start Diagnostic Mode as referenced in the
“Troubleshooting Diagnostics” section in this manual.
2. Exit the Status Check Screen by pressing the
[EXIT]
button (Figure 86).
Figure 86. Status Check Screen
(Diagnostic Mode)
3. Next, press the
[Program/Exit]
button (Figure 87) to
enter the Main Menu.
DEF
E
F
E
F
STATUS CHECK
HOURS
00018.3
CANBUS IS WORKING OK
EXIT
26.8v
[EXIT]
BUTTON
DIAGNOSTIC MODE
Figure 87. Main Screen
4. Press the
[DOWN]
button (Figure 88) to scroll to the
Escape Mode item.
Figure 88. Main Menu (Down Button)
[DOWN]
BUTTON
FAULT DIAGNOSTICS
ABOUT UNIT
USER LOGIN
ESCAPE MODE
UP
DOWN SELECT