49
Auth. Password
: When selecting an authentication type, an authentication password must be provided. This pass-
word must be known by both the Smart Tracker and the SNMP manager’s software package or
MIB browser.
Privacy Type
: Privacy type provides another layer of security between the Smart Tracker and the SNMP manager.
Select from DES or AES. Contact your network administrator for information regarding which type is
required.
Privacy Password
: Privacy password is similar to the authentication password, where the Smart Tracker and the
SNMP manager’s network management software or MIB browser must have knowledge of this
password to complete encryption.
Be sure to save all entered and selected information. The Smart Tracker will automatically restart upon clicking the
“Save & Reboot” button.
SNMP Management Information Base (MIB)
:
The Smart Tracker requires that a MIB file be loaded into the user’s MIB browser or network management software
suite in order for SNMP operating parameters and traps to be passed over a network connection. This is a proprietary
document and may be found on Multilink’s website or by contacting
. All objects and
traps that may be passed over a network connection are described in this document. OID information is provided and
can be visualized using a MIB browser or network management software suite. Refer to the help sections of the user’s
MIB browser or network management software suite to learn how to upload the MIB and begin SNMP communica-
tion with the Smart Tracker. A simple MIB browser for testing SNMP functionality of the Smart Tracker is the
iReasoning MIB Browser. A screen shot of the WALK command showing SNMP functionality is shown below.