User Manual
78
External
Save the waveform onto a USB memory
device
Insert a USB memory device into the port on
the front panel. If the icon
appears on the
top right of the screen, the USB memory
device is installed successfully. If the USB
memory device cannot be recognized, format
the USB memory device according to the
methods in "
The name is default as current system date and
time. The cloned waveform will be saved onto
the USB memory device as a OTA file.
Output
(Generator is available and internal storage is selected)
Output the waveform stored in the selected object.
The following steps take XDS oscilloscope with dual-channel AG for instance.
To save the CH1 waveform and save to the internal/USB memory:
(1)
Push
Save
button.
(2)
Select
Type
in the bottom menu, turn the
M
rotary control to select
Clone
in the
left menu.
(3)
Select
Source
in the bottom menu, select
Mode
as
Out1
. in the right menu.
(4)
Select
AG Output Out1
as
CH1
. in the right menu.
(5)
Select
Line
in the bottom menu. If
a
or
b
is selected, turn the
M
rotary control to
move the cursor. If
ab
is selected, turn the
M
rotary control to move the pair of
cursors. If
x
is selected, the entire screen will be selected automatically.
(6)
Select
Save
in the bottom menu.
To save the waveform to internal memory
, select
Storage
in the right menu
as
Internal
. Turn the
M
rotary control to select an object in the left menu,
select
Save
in the right menu.
To save the waveform onto a USB memory device
, select
Storage
in the
right menu as
External
. Select
Save
in the right menu. An input keyboard
used to edit the file name will pop up. Turn the
M
rotary control to select the
keys, push the rotary control to input. Select the
key in the keyboard to
confirm. The cloned waveform will be saved onto the USB memory device as
a OTA file.
To output the waveform stored in the internal memory
through the generator:
(The generator is optional.)
(1)
Push
Save
button.
(2)
Select
Type
in the bottom menu, turn the
M
rotary control to select
Clone
in the
left menu.
(3)
Select
Save
in the bottom menu, select
Storage
as
Internal
in the right menu.
Содержание MP720021
Страница 1: ...i Digital Storage Oscilloscope 100MHz Model MP720025...
Страница 5: ...v Appendix B General Care and Cleaning 147 Appendix C Battery Using Guide 148...
Страница 27: ...User Manual 22 Control the vertical cursor line Switch to select the lines...
Страница 36: ...User Manual 31 Figure 4 1 Hamming window Figure 4 2 Rectangle window...
Страница 37: ...User Manual 32 Figure 4 3 Blackman window Figure 4 4 Hanning window...
Страница 38: ...User Manual 33 Figure 4 5 Kaiser window Figure 4 6 Bartlett window...
Страница 144: ...User Manual 139 7 Persist on P63 It s normal as the Oscilloscope is working hard on many more data points...