![multicomp pro MP720021 Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/multicomp-pro/mp720021/mp720021_manual_1854297019.webp)
User Manual
14
Warning:
To avoid electric shock, always keep your finger behind the safety guard
ring of the probe during the operation.
To protect you from suffering from the electric shock, do not touch any
metal part of the probe tip when it is connected to the power supply.
Before making any measurements, always connect the probe to the
instrument and connect the ground terminal to the earth.
How to Implement Self-calibration
The self-calibration application can make the oscilloscope reach the optimum
condition rapidly to obtain the most accurate measurement value. You can carry out
this application program at any time. This program must be executed whenever the
change of ambient temperature is 5
℃
or over.
Before performing a self-calibration, disconnect all probes or wires from the input
connector. Push the
Utility
button, select
Function
in the bottom menu, select
Adjust
.
in the left menu, select
Self Cal
in the bottom menu; run the program after everything
is ready.
Introduction to the Vertical System
, there are a few of buttons and rotary controls in
Vertical
Controls
.
The 4 channels are marked by different colors which are also used to mark both the
corresponding waveforms on the screen and the channel input connectors. Press one
of the channel buttons to open the corresponding channel menu, and press again to
turn off the channel.
Press the
Math
button to display the math menu in the bottom. The pink M waveform
appears on the screen. Press again to turn off the math waveform.
The 4 channels use the same
Vertical Position
and
Vertical Scale
rotary controls. If
you want to set the vertical scale and vertical position of a channel, please press CH1,
CH2, CH3 or CH4 at first to select the desired channel. Then turn the
Vertical
Position
and
Vertical Scale
rotary controls to set the values.
Содержание MP720021
Страница 1: ...i Digital Storage Oscilloscope 100MHz Model MP720025...
Страница 5: ...v Appendix B General Care and Cleaning 147 Appendix C Battery Using Guide 148...
Страница 27: ...User Manual 22 Control the vertical cursor line Switch to select the lines...
Страница 36: ...User Manual 31 Figure 4 1 Hamming window Figure 4 2 Rectangle window...
Страница 37: ...User Manual 32 Figure 4 3 Blackman window Figure 4 4 Hanning window...
Страница 38: ...User Manual 33 Figure 4 5 Kaiser window Figure 4 6 Bartlett window...
Страница 144: ...User Manual 139 7 Persist on P63 It s normal as the Oscilloscope is working hard on many more data points...