User Manual
118
(4)
Set the network parameters of the oscilloscope
. In the oscilloscope, push the
Utility
button. Select
Function
in the bottom menu. Select
LAN Set
in the left menu. In the
bottom menu, set the
Type
item
as
LAN
, and select
Set
. In the right menu, set
IP
and
Port
to the same value as the "Ports-settings" in the software in step (3). The Netgate
and Net mask should be set according to the router. Select
Save set
in the bottom
menu, it prompts "Reset to update the config". After resetting the oscilloscope, if you
can get data normally in the oscilloscope software, the connection is successful.
Figure 7-7 Set the network parameters of the oscilloscope
Using Wi-Fi to Connect with PC
(Optional)
Connect with PC as Wi-Fi Access Point
PC should support Wi-Fi.
(1)
Set the oscilloscope.
In the oscilloscope, push the
Utility
button. Select
Function
in
the bottom menu. Select
LAN Set
in the left menu. In the bottom menu, set the
Type
item
as
WIFI-AP
, and select
Set
in the bottom menu.
(2)
In the right menu, select
SSID
, a keyboard will pop up. You can turn and push the
M
rotary control, or touch the keyboard (if the LCD is touchscreen) to set the access
point name.
(3)
In the right menu, select
Encryption
, push again to set the type.
Open
type needs no
password.
WEP
or
WPA
type need to set the password. You can select
WPA
. In the
right menu, select
Password
, use the keyboard to set the Wi-Fi password (8 to 32
characters).
(4)
In the right menu, select
IP:PORT
,
IP
is fixed by the oscilloscope, and can not be
edited. Here IP is 192.168.1.1. Turn the
M
rotary control to set the
PORT
. Here, we
set it to 3000.
(5)
After setting, select
ON
in the
Status
menu. The
icon appears on the top right of
the screen.
Содержание MP720021
Страница 1: ...i Digital Storage Oscilloscope 100MHz Model MP720025...
Страница 5: ...v Appendix B General Care and Cleaning 147 Appendix C Battery Using Guide 148...
Страница 27: ...User Manual 22 Control the vertical cursor line Switch to select the lines...
Страница 36: ...User Manual 31 Figure 4 1 Hamming window Figure 4 2 Rectangle window...
Страница 37: ...User Manual 32 Figure 4 3 Blackman window Figure 4 4 Hanning window...
Страница 38: ...User Manual 33 Figure 4 5 Kaiser window Figure 4 6 Bartlett window...
Страница 144: ...User Manual 139 7 Persist on P63 It s normal as the Oscilloscope is working hard on many more data points...