6.
Install installation/removal jig on the cylinder
head.
7.
Remove injector with installation/removal jig.
8.
Remove the installation/removal jig.
9.
Remove sealing ring (4) from injector or use a
self-made wire hook or magnet to take it out
of the cylinder head.
Note:
The sealing ring (4) for sealing the combus-
tion chamber must only be used once.
10.
Dispose of sealing ring (4) and injector.
11.
Clean all mating and sealing surfaces.
12.
Cover all connections and bores, or seal with
suitable plugs.
Installing new injector
Note:
• The new sealing ring is included in the
scope of supply of the injector.
• A multi-purpose grease without solids con-
tent must be used.
1.
Install new sealing ring (1) abutted to (Multi-
purpose grease) and ensure that the installa-
tion position is correct.
MS150093/05E 2018-12
| Injector | 213
TIM-ID: 0000077484 - 002