500 – AL Wiring POM Starter 1
ZKP-Number: 14.500.900
Cause
Corrective action
A cabling fault in connection of
starter 1 of CPM has been
detected. This may be due to a
missing consumer, wire break or a
short circuit.
u
Check connection between POM and starter.
501 – AL Wiring POM Starter 2
ZKP-Number: 14.500.901
Cause
Corrective action
A cabling fault in connection of
starter 2 of CPM has been
detected. This may be due to a
missing consumer, wire break or a
short circuit.
u
Check connection between POM and starter.
502 – AL Open Load POM Alternator
ZKP-Number: 14.500.902
Cause
Corrective action
A line interruption was detected
at the battery-charging
connection for the POM
u
Check connection between POM and battery-charging generator.
503 – AL Battery Not Charging
ZKP-Number: 14.500.903
Cause
Corrective action
Battery is not charged by battery-
charging generator
u
Check battery-charging generator and cabling.
504 – AL CAN POM Node Lost
ZKP-Number: 14.500.904
Cause
Corrective action
POM missing on CAN bus
u
Check connection and POM.
506 – AL Low Starter Voltage
ZKP-Number: 14.500.906
Cause
Corrective action
The battery voltage is too low for
the starting process
u
Check starter battery and cabling.