397 – TD P-Oil Sensor Deviation
ZKP-Number: 1.0480.293
Cause
Corrective action
Maximum lube oil pressure
deviation
1. Check wiring and sensor.
2. Contact Service.
400 – AL Open Load Digital Input 1
ZKP-Number: 2.8006.625
Cause
Corrective action
Line disruption on digital input 1.
Cabling faulty or no resistance
over switch
1. Check cabling.
2. Check target device input.
3. Contact Service.
401 – AL Open Load Digital Input 2
ZKP-Number: 2.8006.626
Cause
Corrective action
Line disruption on digital input 2.
Cabling faulty or no resistance
over switch
1. Check cabling.
2. Check target device input.
3. Contact Service.
402 – AL Open Load Digital Input 3
ZKP-Number: 2.8006.627
Cause
Corrective action
Line disruption on digital input 3.
Cabling faulty or no resistance
over switch
1. Check cabling.
2. Check target device input.
3. Contact Service.
403 – AL Open Load Digital Input 4
ZKP-Number: 2.8006.628
Cause
Corrective action
Line disruption on digital input 4.
Cabling faulty or no resistance
over switch
1. Check cabling.
2. Check target device input.
3. Contact Service.
404 – AL Open Load Digital Input 5
ZKP-Number: 2.8006.629
Cause
Corrective action
Line disruption on digital input 5.
Cabling faulty or no resistance
over switch
1. Check cabling.
2. Check target device input.
3. Contact Service.
170 | Troubleshooting | MS150093/05E 2018-12